SMOKE-FACTORY –
DATA II Operating Instructions
5.3 Control choices
5.3.1 External control
You may control the DATA II externally through the XLR sockets .
Please note: DMX takes priority. That means: when the machine is controlled
via DMX 512 this data takes priority over 0-10 V (+) DC and Stand alone operation. Also there are
optional avalible:
cable remote
radio remote
5.3.2 Operating via DMX 512
Connecting the DATA II to a DMX-desk use the 5pin XLR socket . As soon as the machine receives a
correct DMX signal, the yellow DMX-LED shines. Now the pump and the fan can be adjusted via the
desk.
Please note: If a fan is connected to the machine, the DATA II uses two channels at your desk.
Channel 1 = Pump, Channel 2 = Fan.
Adjusting the DMX start address
Press the Mode-button at the control panel, until three figures will appear
on the LED display
Adjust the requested start address by pressing the Up/Down-buttons .
Save the start address by pressing the Enter-button once. The start address will also be
saved when you disconnect the machine from the mains supply.
Now the pump and the fan can be adjusted via the desk.
When you switch off the DMX signal, the machine will be switched off automatically after 15
seconds.