Decode UPC/EAN Supplementals
Parameter # 0x10
Supplementals are appended characters (2 or 5) according to specific code format
conventions (e.g., UPC A+2, UPC E+2). Several options are available:
If Decode UPC/EAN with Supplemental characters is selected, the scanner does
not decode UPC/EAN symbols without supplemental characters.
If Ignore UPC/EAN with Supplemental characters is selected, and the
SE 824 is presented with a UPC/EAN symbol with a supplemental, the scanner
decodes the UPC/EAN and ignores the supplemental characters.
If Autodiscriminate UPC/EAN Supplementals is selected, scan Decode UPC/
EAN Supplemental Redundancy on page 20, then select a value from the
numeric bar codes beginning on page 83. A value of 5 or more is
recommended.
•Select Enable 378/379 Supplemental Mode to enable the SE 824 to identify
supplementals for EAN-13 bar codes starting with a ‘378’ or ‘379’ prefix only. All
other UPC/EAN bar codes are decoded immediately and the supplemental
characters ignored.
•Select Enable 978 Supplemental Mode to enable the SE 824 to identify
supplementals for EAN-13 bar codes starting with a ‘978’ prefix only. All other UPC/
EAN bar codes are decoded immediately and the supplemental characters
ignored.
•Select Enable Smart Supplemental Mode to enable the SE 824 to identify
supplementals for EAN-13 bar codes starting with a ‘378’, ‘379’, or ‘978’ prefix only.
All other UPC/EAN bar codes are decoded immediately and the supplemental
characters ignored.
Note: To minimize the risk of invalid data transmission, we recommend
selecting whether to read or ignore supplemental characters.
Select the desired option by scanning one of the following bar codes.
Decode UPC/EAN With Supplementals
(0x01)