EasyManua.ls Logo

SolarEdge SE12.5k

SolarEdge SE12.5k
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SE2200 SE3000 SE3500 SE4000
SE4000-
16A
SE5000 SE6000 Unit
Emissions
IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12,
FCC part 15 class B
RoHS Yes
Installation Specifications
AC output Cable Gland - diameter 9-16 mm
DC input
(1)
1 MC4 pair 2 MC4 pairs
Dimensions (W x L x
H)
540 x 315 x 172 540 x 315 x 191 mm
Weight 20.2 21.7 kg
Cooling Natural Convection
Noise (typical) < 50 dBA
Operating
temperature range
(2)
-20 - +50 (M40 version -40 to + 50) °C
Maximum altitude 2000 m
Operating humidity –
non condensing
< 95 %
Protection Rating /
Environmental
category
IP65Outdoor and Indoor
Pollution degree
classification (inside
/ outside)
2/3
Bracket mounted (bracket provided)
(1)
Connection of additional strings in parallel to a single input is allowed as long as the cumulative current does not
exceed 45A.
(2)
For inverter power derating refer to the application note at the following link:
http://www.solaredge.com/files/pdfs/se-temperature-derating-note.pdf
-Three Phase System Installation Guide MAN-01-00057-4.1
104Technical Specifications - Single Phase Inverters (Europe &APAC)

Table of Contents

Related product manuals