NOTE
There are no LED indicators on the Ethernet connector, if the inverter is not
communicating with the Monitoring platform through a LAN refer to
"Troubleshooting Communication" on page70
LAN Configuration
1.
The inverter is configured by default to LAN. If reconfiguration is required:
a. Verify the ON/OFF/P switch is OFF.
b. Verify the AC is on.
c.
Close the cover and turn ON the Synergy Manager.
WARNING!
ELECTRICAL SHOCK HAZARD. Do not touch uninsulated wires when
the Connection Unit cover is removed.
d. Use the SolarEdge SetApp to access the Commissioning main menu screen as
described in "Activating, Commissioning and Configuring the System" on
page45"Activating, Commissioning and Configuring the System" on page45 .
e.
From the Commissioning screen, tap Communication.
f.
Select Configure Ethernet, to configure the connection.
2.
Verify the connection, as described in "RS485 Bus Configuration" on page64
NOTE
The system automatically establishes communication with the
monitoring platform as it is configured to LANby default.
NOTE
If your network has a firewall, you may need to configure it to enable
the connection to the following address:
Destination Address: prodssl.solaredge.com
Modbus TCP Port: 443 (for incoming and outgoing data)
Chapter 6: Setting Up Communication with the Monitoring Platform 60
Three Phase Inverter with Synergy Technology P/N: SExxK-xxxxIxxxx SExxK-xxxxIxxxx