STANDARD COMPLIANCE
Safety
IEC-60730 -1
Emissions
EN61000-6-1,2,3; EN61000-4-
2,3,4,5,6,8,11; EMC directive
2014/30/EU
Radio
ETSI EN 300 328 V 1.8.1; ETSI EN 301
489-1; ETSI EN 301 489-17
INSTALLATION SPECIFICATIONS
Dimensions (H x W x D) 375 x 240 x 110 / 14.7 x 9.5 x 4.5 mm/ in
Weight 5.3 / 11.7 kg/ lb
Operating Temperature Range -10 to +50 / 14 to 122 °C / °F
Cable Gland Diameters
2 glands 6-12, 1 gland 4-8
mm
Terminal Block Minimum Wire
Cross Section
15 / 1.5 AWG/mm
2
Maximum distance between
Device and Load/ Cable cross
section - for load size 3.0kW
3/10for 15 AWG/1.5 mm
2
20/65for 13 AWG/ 2.5 mm
2
m/ft
Protection Rating
IP65
Mounting Type Wall mount
Mechanical specifications (mm):
Smart
Energy
Hot
Water
Specifications
MAN-01-00572-1.1