Modifying the Device Operation Mode and Schedules
You can re-configure the device operation mode and schedules at any time, using the
monitoring platform.
To Do this
Manually turn the load on or off
Select the device from the Device Manager
screen. Select Mode è Manual and set the
device to either ON or OFF.
Disconnect the device(s) from the
network
Select Remove Device or Remove All from the
device screen.
Modify the schedule configuration
(only for inverters with an LCD)
Select the device from the Device Manager
screen. Select Mode è Auto and set the
parameters of any menu: Smart
Save/Schedule.
Disable or delete a schedule (only for
inverters with an LCD)
Select Disable or Remove Schedule from the
Schedule screen.
Verifying the Connection
Inverters with LCD
1.
Check the status screens:
HA devices status
, showing the device name and state: ON, OFF, or an asterisk
(*), which indicates no communication with the device:
H A D e v i c e s S t a t u s :
R E G 0 1 1 < O N >
Communication
status, showing the number of communicating HAdevices
(under Prot) and the number of detected devices (under ##):
D e v P r o t # #
R S 4 8 5 - 1 < - - - > < - - > < - >
Z i g B e e < H A > < 1 > < 1 >
2.
To check the device details, from the device configuration screen, select Device
Info. The following screen is displayed:
Smart Energy Hot Water Installation Guide MAN-01-00570-1.4