What to do if SolaX Power Battery Charger shows input over voltage?
V
Victoria SmallAug 16, 2025
If your SolaX Power Battery Charger indicates an input over voltage, it may be due to the AC input voltage being too high. First, check the input voltage from the backend. If the voltage exceeds 276Vac for a short period, wait for the power grid to return to the normal voltage range.
L
lisa26Aug 18, 2025
Why SolaX Power Battery Charger shows input lower voltage?
N
navarrorobertAug 19, 2025
If your SolaX Power Battery Charger indicates an input lower voltage, this could be because the AC input voltage is too low. You should check the input voltage from the backend. If the voltage is under 184Vac for a short time, wait until the power grid recovers to the normal voltage range.
K
Kristen FernandezAug 22, 2025
How to fix SolaX Power Battery Charger input over current?
A
Amber SmithAug 22, 2025
If the SolaX Power Battery Charger is showing an input over current, it means the AC input current may be too large. Immediately shut off the leakage current protection switch of the power distribution cabinet. Also, check for any low resistance connections between the AC output cables of the charger.
N
Nicholas WestAug 25, 2025
What causes over leakage current in SolaX Power Battery Charger?
T
Timothy ReyesAug 26, 2025
An over leakage current in your SolaX Power Battery Charger indicates that the leakage current to the earth may be too high. Immediately shut off the leakage current protection switch of the power distribution cabinet. Check for any broken AC output cables or low resistance connections to the earth.
A
Alexander Parks IIIAug 28, 2025
What to do if SolaX Power Battery Charger has grounding fault?
J
Joseph NelsonAug 28, 2025
If your SolaX Power Battery Charger is showing a grounding fault, it may be due to an inappropriate grounding connection of the input/output cables or an inverse connection of the L/N input cables. Immediately shut off the leakage current protection switch of the power distribution cabinet. Check if the AC input/output cables are normal, and verify that there is no inverse connection of the L/N input cables.
K
kennethclarkeAug 31, 2025
What to do if leakage current sensor is abnormal in SolaX Power Battery Charger?
B
Benjamin SolomonAug 31, 2025
If your SolaX Power Battery Charger displays that the leakage current sensor is abnormal, it means the detection of the leakage current sensor is abnormal. Immediately shut off the leakage current protection switch of the power distribution cabinet. Check for any broken AC output cables or low resistance connections to the earth.
C
Crystal GonzalezSep 3, 2025
What to do if SolaX Power Battery Charger shows input over frequency?
S
Sarah PetersSep 3, 2025
If your SolaX Power Battery Charger indicates an input over frequency, it means the AC input frequency may be too high. First, check the input voltage frequency from the backend. If the frequency exceeds 55Hz for a short time, wait for the power grid to recover to the normal voltage range.
K
kimberly01Sep 6, 2025
Why SolaX Power Battery Charger shows input lower frequency?
R
Richard Davidson MDSep 6, 2025
If your SolaX Power Battery Charger indicates an input lower frequency, it means that the AC input frequency may be too low. You should check the input voltage frequency from the backend. If the frequency is lower than 45Hz for a short time, wait until the power grid recovers to the normal voltage range.
T
Tyler CarneySep 9, 2025
What causes over temperature in SolaX Power Battery Charger?
S
Steven JohnsonSep 9, 2025
An over temperature issue in your SolaX Power Battery Charger may be caused by the temperature being too high inside the charger. Check the surrounding conditions of the installed chargers to see if there is a heating device nearby. Ensure the environmental temperature is below 60 degrees.
Details on charger performance, including LED indicators, RFID card functionality, emergency stop, and key characteristics like IP65 rating and low standby power.