3) EPS Mute
Setting
Setting
> Mute:
Yes
EPS Mute
>Min SOC:
10%
Self-use Mode
>Charge from grid
Disable
Self-use Mode
>Charge battery to
90%
Self-use Mode
>Min SOC:
10%
Feed-in Priority
>Charge battery to
90%
Feed-in Priorty
90
91
4) Self-use mode
In this mode, you can set the power reserve percentage of the minimum
battery state, set whether the power can be taken from the mains side to
charge the battery, and set the amount of power to charge the battery.
For example: set the reserved minimum SOC of the battery capacity to
"10%", which means that when the battery has been discharged to 10% of
the battery capacity, the battery is not allowed to continue to discharge;
When Charge from grid is set to "Enable", the utility power is allowed to
charge the battery; when set to “Disable”, the utility power is not allowed to
charge the battery;
Charge battery to is set to 90%, indicating that the mains is allowed to
charge the battery at 90%.
5) Feed-in Priority
In this mode, you can set the power reserve percentage of the minimum
battery state, set whether the power can be taken from the mains side to
charge the battery, and set the amount of power to charge the battery.
For example: set the reserved minimum SOC of the battery capacity to
"10%", which means that when the battery has been discharged to 10% of
the battery capacity, the battery is not allowed to continue to discharge;
Charge battery to is set to 90%, indicating that the mains is allowed to
charge the battery at 90%.
>Min SOC:
10%
Backup mode
Backup mode
>Charge battery to
90%
7) Charge and discharge period
Here you can set the charge and discharge time period.
If two charging and discharging periods are needed, turn on the charging
and discharging period 2 and set the period.
6) Backup mode
In this mode, you can set the power reserve percentage of the minimum
battery state, set whether the power can be taken from the mains side to
charge the battery, and set the amount of power to charge the battery.
For example: set the reserved minimum SOC of the battery capacity to
"30%", which means that when the battery has been discharged to 10% of
the battery capacity, the battery is not allowed to continue to discharge;
Charge battery to is set to 90%, indicating that the mains is allowed to
charge the battery at 90%.
> Forced Charg Period
Start Time
00:00
Chrg&DischrgPeriod
>Forced Charg Period
End Time
00:00
>Allowed Disc Period
Start Time
00:00
>Allowed Disc Period
End Time
00:00
>Function
Enable/Disable
Chrg&DischrgPeriod2
Chrg&DischrgPeriod
>Allowed Disc Period
00:00
Chrg&DischrgPeriod
>Allowed Disc Period
End Time
00:00
Chrg&DischrgPeriod
Start Time
Chrg&DischrgPeriod2
Chrg&DischrgPeriod2
> Forced Charg Period
Start Time
00:00
Chrg&DischrgPeriod2
>Forced Charg Period
End Time
00:00
Chrg&DischrgPeriod2
No
Charge from grid
Chrg&DischrgPeriod2
Chrg&DischrgPeriod
Here you can choose whether the buzzer is turned on when the
inverter is running in EPS mode. Select Yes, the buzzer mutes, select
NO, EPS mode, the buzzer will sound once every 4s when the battery
is fully charged, the closer the battery is to the empty state, the
higher the buzzer will sound, to remind users to avoid battery loss.