2. The activated burner’s power will change in increments, to reach the level corresponding to the
touching point. Set the power level using this method within not more than 5 seconds. After 5
seconds of completing the last change of pad power, the control pad of the controller will stop
receiving further instructions, and a new power value of the selected burner will be set as specified
in the preceding step.
Follow the same procedure with each burner.
You may touch the sensors described above at any time to set the desired heating power of burner,
in the range from 1 to 9.
After each change of the selected burner’s power setting, the row of LEDs will light up, then go
off after a short time, with only the modified power setting of the active burner being displayed.
When you have started all burners, their power settings are displayed accordingly and the LED
row – no 4. fig. 2 is off. Burners that have not been switched on in the relevant controller field
corresponding to the burner indicated on the panel will remain off and not light up.
If the burner heating power level is set from 1 to 9, the burner will operate in pulse mode,
meaning that when the burner is not burning gas (several to several tens of seconds in one
cycle), it re-circulates heat from incandescent hearth to heating pad of the ceramic panel, thus
achieving better gas intake efficiency.
At first (cold) run of burner(s), they heat up during several minutes, to switch to pulse
operating mode after that time, depending on the heating power settings.
-TIMER function, touch the burner selection fields twice (Fig.2, no 5,6,7 or 8), touch “+” and “-“
to select time in minutes (from 1 to 99 min.), the burner stops automatically after selected time
3.3. Description of operating condition with intelligent preheating function.
The hob operating status with reheating is a transitory condition for rapid achievement
of target temperature of the active hot field, up to the heating power set. It is signaled by the
decimal point lighting up next to the active burner’s digital indicator (5,6, fig 2).
1. If any level of heating power is set for the given hot field, the controller display will show a
number corresponding to the power setting. With this setting, the operating condition with
automatic reheating function will start automatically. This status is additionally signaled by
decimal point on the display corresponding to the given hot field. It takes up to 18 minutes,
depending on the power setting. Then, the hob’s controller switches to automatic heating cycles.
2. You can change the heating power level of the selected sensor while working with automatic
preheating function using the corresponding sensor and following the procedure described above
under. 3.2.
3. The automatic preheat operating mode of the given burner is automatically controlled by
an electronic system. The user can switch off the function by sliding the finger to “0” power
level and then immediately to any chosen power level (from 1 to 9)
3.4. Switching off the burners.
In order to switch off any of the operating burners, touch the corresponding sensor, then slide
your finger along the slider towards the “key” so that to reduce the burner’s power setting to “0”
(gas supply shutdown). During this operation, the row of LEDs (no 4 fig. 2) showing the power
level goes down and the digits decrease from the level previously set to level “0”. When level “0”
is reached and the controller is ready for restarting, the letter “H” will display after a moment,
indicating that the panel is hot in the location of the burner that has just been shut down.
You may also switch off the entire hob. To do so, touch the main shutdown switch sensor, or
press and hold the power setting slider around zero power for some time, having previously