What to do if SOLIS RHI-6K-48ES-5G detects ARC in DC circuit?
- TTony BarnettSep 10, 2025
If your SOLIS Inverter detects an ARC in the DC circuit, check the PV connections for any signs of arcing and then restart the inverter.
What to do if SOLIS RHI-6K-48ES-5G detects ARC in DC circuit?
If your SOLIS Inverter detects an ARC in the DC circuit, check the PV connections for any signs of arcing and then restart the inverter.
How to fix no grid voltage on SOLIS Inverter?
If your SOLIS Inverter shows no grid voltage, check the connections and grid switch. Also, check the grid voltage inside the inverter terminal.
What to do if my SOLIS RHI-6K-48ES-5G is overheating?
If your SOLIS Inverter is overheating, check the ventilation around the inverter to ensure it is properly ventilated. Also, verify that the inverter isn't exposed to direct sunlight during hot weather.
How to resolve over DC voltage on SOLIS Inverter?
If you are experiencing an over DC voltage issue with your SOLIS Inverter, reduce the number of modules in series.
What to do if SOLIS RHI-6K-48ES-5G Inverter displays over grid current?
If your SOLIS Inverter is showing over grid current, try restarting the inverter. If the problem persists, the power board may need to be changed.
How to fix DC input overcurrent on SOLIS RHI-6K-48ES-5G?
To address a DC input overcurrent issue on your SOLIS Inverter, first, try restarting the inverter. If the issue continues, identify and remove the string connected to the faulty MPPT. As a last resort, the power board may need replacement.
How to resolve high grid impedance on SOLIS RHI-6K-48ES-5G?
To address high grid impedance with your SOLIS Inverter, use the user define function to adjust the protection limit, if it's allowed by your electrical company.
What to do if SOLIS RHI-6K-48ES-5G Inverter shows unconnected battery error?
If your SOLIS Inverter displays an unconnected battery error, verify that the battery power wire is correctly connected. Also, check that the output voltage of the battery is correct.
How do I fix under grid frequency on SOLIS Inverter?
If your SOLIS Inverter is showing an under grid frequency error, use the user define function to adjust the protection limit, if your electrical company allows it.
How to troubleshoot battery overvoltage hardware fault on SOLIS RHI-6K-48ES-5G?
If your SOLIS Inverter is showing a battery overvoltage hardware fault, check the circuit to see if the battery circuit jumps. You can also try restarting the inverter.
Identifies hazard symbols and their meanings used in the manual.
Provides essential safety guidelines for inverter installation and operation.
Criteria for choosing an optimal and safe installation location for the inverter.
Instructions and diagrams for securely mounting the inverter on a wall.
Steps for correctly assembling MC4 connectors for PV input.
Guidelines for connecting battery terminals and using appropriate connectors.
Detailed procedure for assembling the AC connector for the inverter.
Information on connecting Acrel or Eastron meters for monitoring and control.
Section for modifying Time/Date, Slave address, and system language.
Provides access to detailed information such as alarm, running messages, and versions.
Access to advanced settings requiring technician authorization and password.
Lists compatible battery modules and configuration options.
Configuration of the inverter's five different storage operating modes.
Configuration options for controlling the power exported to the grid.
Enables and manages the Arc Fault Circuit Interrupter function for fire prevention.
Checks and preparations required before initiating inverter commissioning.
Step-by-step guide for the initial startup and configuration of the inverter.
Steps for safely shutting down the inverter and the system.