EasyManua.ls Logo

SOLIS RHI Series User Manual

SOLIS RHI Series
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
In st ru ct i on M an u al
Soli s R HI Seri es Hybri d Inverter
G i nlon g Tech nolog i es C o., Lt d.
G i nlong Tech n olog i e s C o., Ltd.
No. 57 Ji n t on g R oad, B i n h ai Indu stri al P ark , Xi an g sh an , Ni ng bo,
Zh eji an g , 3 1 571 2 , P.R .C h i na.
Tel: +86 ( 0) 574 6578 1 806
Fax: +86 ( 0) 574 6578 1 606
If you encou nter an y problem on t h e i nvert er, please f i n d ou t t h e i nvert er S/N
an d con tact u s, w e w i ll t ry t o respond to y ou r q u est i on A SA P .
P lease adh ere to th e act u al produ cts i n case of any di screpan ci es i n t h i s u ser m an u al.
( R HI-3 P ( 5-1 0) K-H VE S-5G )
Ver1 .1
( Fo rA u strali a)
Question and Answer IconNeed help?

Do you have a question about the SOLIS RHI Series and is the answer not in the manual?

SOLIS RHI Series Specifications

General IconGeneral
TypeHybrid Inverter
Protection RatingIP65
Number of MPPTs2
Battery Voltage48V
Output Voltage230V
Communication InterfacesRS485, Wi-Fi
Operating Temperature Range-25°C to 60°C
Max. Charging Current100A
Max. Discharging Current100A
Frequency50Hz/60Hz

Summary

Safety and Warning Guidelines

Safety Definitions

Defines safety terms used in the manual: DANGER, WARNING, CAUTION, and NOTE for hazard identification.

General Safety Instructions

Provides essential safety instructions for installation and operation, including electrical safety and personal protection.

Installation Procedures

PV Input Terminal Assembly

Explains how to connect PV strings to the inverter using MC4 connectors, emphasizing voltage and polarity.

Battery Terminal Connection

Provides step-by-step instructions for connecting the battery using quick connectors, including cable preparation and torque.

AC Connector Assembly

Details the assembly of the AC connector, including cable specifications, wire stripping, and terminal connections for grid and backup.

Operation and Settings

Alarm Messages

Displays the 100 latest alarm messages, allowing scrolling and manual review of fault conditions.

Selecting Grid Standard

Allows selection of the grid's reference standard (e.g., G98, G99) based on local requirements.

Grid Switches Control

Enables or disables the inverter's generation function by switching the grid connection ON or OFF.

Battery Control Settings

Used to select the compatible battery module and configure battery wakeup functions.

Backup Control Settings

Configures the backup port, allowing enabling/disabling of the connection and setting backup parameters.

Export Power Settings

Allows configuration of export power control features like EPM ON/OFF, Backflow Power, and Failsafe.

AFCI Function

Details the Arc Fault Circuit Interrupter (AFCI) function for detecting DC arc faults and preventing fires.

Enable AFCI Function

Explains how to enable the AFCI function via the advanced settings menu, requiring technician-level access.

AFCI Function Operation

Describes the inverter's behavior during an arc fault detection, including shutdown and alarm messages.

Commissioning and Shutdown Procedures

Troubleshooting Faults

Fault Checking Steps

Guides users on how to check for and diagnose fault conditions displayed on the inverter's screen.

Fault Message and Solution Table

Lists common alarm messages, their failure descriptions, and recommended solutions for troubleshooting.

Inverter Specifications

Technical Specifications

Presents technical specifications for the RHI series inverters, covering DC input, battery, and AC output parameters.

Related product manuals