Installation and Operation Manual
Solis 4G Three Phase Inverter
(12-20kW)
Ver 1.1
Ginlong (Ningbo) Technologies Co., Ltd.
Ningbo Ginlong Technologies Co., Ltd.
No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo,
Zhejiang, 315712, P.R.China.
Tel: +86 (0)574 6578 1806
Fax: +86 (0)574 6578 1606
If you encounter any problem on the inverter, please find out the inverter S/N
and contact us, we will try to respond to your question ASAP.

Questions and Answers

  • A
    Anne CooperAug 11, 2025
    Why is my SOLIS Solis-3P12K-4G not getting any power?
    • L
      Lisa KnightAug 11, 2025
      If your SOLIS Inverter is not powering on, there are several things to check: * Verify the PV input connections. * Ensure the DC input voltage is adequate (single phase >120V, three phase >350V). * Confirm that the PV+/- polarity is not reversed.
  • B
    brookslisaAug 18, 2025
    What to do if my SOLIS Inverter shows OV-G-V01/02/03/04 error?
    • P
      Peter ReyesAug 18, 2025
      If your SOLIS Inverter displays the error OV-G-V01/02/03/04, it could be due to a high resistance in the AC cable. Try replacing it with a larger size grid cable. Alternatively, if permitted by your electrical company, adjust the protection limit.
  • J
    James GrantAug 27, 2025
    What to do if my SOLIS Solis-3P12K-4G Inverter displays UN-G-V01/02 error?
    • W
      Wayne SpencerAug 27, 2025
      If your SOLIS Inverter displays the error UN-G-V01/02, use the user define function to adjust the protection limit if it’s allowed by electrical company.
  • M
    masonmartinSep 3, 2025
    How to fix SOLIS Solis-3P12K-4G Inverter when LCD shows initializing all the time?
    • C
      Cynthia BurkeSep 3, 2025
      If the LCD screen on your SOLIS Inverter is stuck on the initializing screen, check the following: 1. Make sure the connectors on the main board and power board are securely attached. 2. Verify that the DSP connector to the power board is also firmly connected.

SOLIS Solis-3P12K-4G Specifications

General IconGeneral
ModelSolis-3P12K-4G
Rated Power12kW
Input Voltage Range200-1000V
Max. Input Voltage1100V
Number of MPPTs2
Nominal AC Output Power12kW
AC Voltage Range310-480 V
Nominal Grid Frequency50/60 Hz
Total Harmonic Distortion (THD)<3%
Euro Efficiency98.2%
DC SwitchYes
Protection DegreeIP65
Cooling MethodNatural convection
Max. DC Input Power18kW
MPPT Voltage Range200-850V
Max. AC Output Power13.2 kW
Nominal AC Voltage230/400 V
Power Factor0.8 leading to 0.8 lagging
Operating Temperature Range-25°C to +60°C
CommunicationRS485
Humidity0-100% (non-condensing)
Warranty5 years standard