Installation and Operation Manual
Solis Three Phase Inverter
Solis-(75-110)K-5G-PRO
Ginlong Technologies Co., Ltd.
Ginlong Technologies Co., Ltd.
No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo,
Zhejiang, 315712, P.R.China.
Tel: +86 (0)574 6578 1806
Fax: +86 (0)574 6578 1606
If you encounter any problem on the inverter, please find out the inverter S/N
and contact us, we will try to respond to your question ASAP.
Please adhere to the actual products in case of any discrepancies in this user manual.
Ver 1.1

Table of Contents

Questions and Answers

  • E
    Ethan PetersenAug 13, 2025
    What to do if my SOLIS Inverter shows 'Screen OFF with DC applied'?
    • K
      Katherine CollinsAug 13, 2025
      If the screen is off while DC is applied, it could be due to internal damage to the inverter. In this case, do not turn off the DC switches, as it will damage the inverter. Wait for solar irradiance to reduce, confirm the string current is less than 0.5A with a clip-on ammeter, and then turn off the DC switches. Note that damages due to wrong operations are not covered under warranty.
  • K
    Kathy DavisAug 16, 2025
    What to do if my SOLIS Inverter displays 'ILeak-PRO 01/02/03/04' error?
    • L
      Leslie ParksAug 17, 2025
      If your SOLIS Inverter is showing an 'ILeak-PRO 01/02/03/04' error, check both the AC and DC connections. Additionally, inspect the cable connections inside the inverter.
  • J
    John WilsonAug 21, 2025
    What should I do if my SOLIS Inverter displays 'PV ISO-PRO 01/02'?
    • S
      Sara MartinAug 21, 2025
      If your SOLIS Inverter shows a 'PV ISO-PRO 01/02' error, remove all DC input, reconnect, and restart the inverter one by one. You should also identify which string is causing the fault and check the isolation of that string.
  • Z
    zwhiteAug 25, 2025
    What to do if my SOLIS Solis-75K-5G-PRO has arcing protection (model with AFCI module)?
    • B
      Brandon MillerAug 25, 2025
      If your SOLIS Inverter (model with AFCI module) activates arcing protection, check the inverter connection for any signs of an arc and then restart the inverter.
  • D
    dominique94Aug 28, 2025
    What does 'Reve-DC' mean on my SOLIS Solis-75K-5G-PRO and how to fix it?
    • R
      richardwhitakerAug 28, 2025
      If your SOLIS Inverter displays 'Reve-DC', check the PV string polarity. If any strings are reversely connected, wait until night when solar irradiance is low and the PV string current drops below 0.5A. Then, turn off the two DC switches and correct the polarity issue.
  • J
    jenniferhillSep 1, 2025
    What does it mean if my SOLIS Solis-75K-5G-PRO Inverter shows 'RelayChk-FAIL'?
    • A
      Anthony NelsonSep 1, 2025
      If your SOLIS Inverter is showing a 'RelayChk-FAIL' message, restart the inverter. If the issue persists, contact your installer.
  • B
    Barbara AnthonySep 5, 2025
    What does it mean if my SOLIS Inverter has AFCI self-detection (model with AFCI module)?
    • J
      James HigginsSep 5, 2025
      If your SOLIS Inverter (model with AFCI module) is showing an AFCI self-detection issue, restart the inverter. If the problem continues, contact a technician.
  • R
    rachel06Sep 8, 2025
    How to fix 'INI-FAULT' on SOLIS Inverter?
    • J
      jordancunninghamSep 8, 2025
      To address an 'INI-FAULT' on your SOLIS Inverter, try restarting the inverter. If the issue persists, contact your installer for further assistance.

SOLIS Solis-75K-5G-PRO Specifications

General IconGeneral
ModelSolis-75K-5G-PRO
Rated Output Power75 kW
Max. DC Input Power112.5 kW
Max. Input Voltage1100 V
Start-up Voltage250 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of DC Inputs per MPPT2
Max. AC Apparent Power82.5 kVA
Max. Output Current120 A
Rated Grid Voltage400 V
Grid Voltage Range320-480 V
Rated Grid Frequency50/60 Hz
THDi<3%
Protection ClassIP66
Maximum DC Input Power112.5 kW
Maximum DC Input Voltage1100 V
Maximum Efficiency98.7%
European Efficiency98.4%
TypeString Inverter
Operating Temperature Range-25°C to +60°C
CommunicationRS485, WiFi
Grid StandardsIEC 62109, VDE-AR-N 4105