If you encounter any problem on the inverter, please find out the inverter S/N
and contact us, we will try to respond to your question ASAP.
Please adhere to the actual products in case of any discrepancies in this user manual.
Solis S5-EH1P-L Hybrid Inverter
Ver1.0
(ForAustralia)

Questions and Answers

  • L
    Linda WangSep 12, 2025
    What does 'OV-TEM' mean on my SOLIS S5-EH1P5K-L Inverter?
    • S
      skellySep 12, 2025
      If your SOLIS Inverter displays 'OV-TEM', check the inverter's surrounding ventilation. Also, see if direct sunlight is hitting the inverter during hot weather.
  • R
    raymondlarsonAug 25, 2025
    What to do if SOLIS S5-EH1P5K-L Inverter shows a Surge Alarm?
    • L
      Lisa ThompsonAug 25, 2025
      If your SOLIS Inverter displays a 'Surge Alarm', it indicates a surge on the grid side. First, try restarting the device. If the alarm persists after restarting, it means the issue hasn't been resolved and you should contact the manufacturer's customer service for further assistance.
  • S
    ssimmonsAug 25, 2025
    Why does my SOLIS S5-EH1P5K-L show OV-G-V01 error?
    • J
      Justin MillerAug 26, 2025
      If your SOLIS Inverter shows the error 'OV-G-V01', it means the grid voltage is exceeding the upper voltage range. To address this: 1. Check to see if there are any known issues with the power grid in your area. 2. Make sure the AC cable is securely and correctly connected. 3. Restart the inverter to see if the problem goes away.
  • S
    Stacey DiazSep 23, 2025
    What does 'UN-G-F01/02' mean on my SOLIS S5-EH1P5K-L?
    • K
      Kristi HowardSep 23, 2025
      If your SOLIS Inverter displays 'UN-G-F01/02', use user define function to adjust the protection limit if it’s allowed by electrical company.
  • S
    Stacey BensonSep 12, 2025
    Why does my SOLIS S5-EH1P5K-L LCD show initializing all the time?
    • M
      Michael HendersonSep 12, 2025
      If your SOLIS Inverter displays 'LCD show initializing all the time', check if the connectors on the main board or power board are securely fixed. Also, check if the DSP connector to the power board is fixed.
  • E
    Earl DelgadoSep 16, 2025
    What does 'OV-Vbatt1' mean on my SOLIS S5-EH1P5K-L and how do I troubleshoot it?
    • A
      Alexandria GreenSep 16, 2025
      If your SOLIS Inverter displays 'OV-Vbatt1', check if the over voltage protection point is set correctly. You can also try restarting the inverter.
  • P
    phillipspaulSep 5, 2025
    What does INI-FAULT (1031 DATA:0000) mean on my SOLIS S5-EH1P5K-L?
    • M
      Megan AshleySep 5, 2025
      If your SOLIS Inverter displays 'INI-FAULT (1031 DATA:0000)', it means there is an AD zero drift overlink. Restart the system to see if the error disappears.
  • M
    Michele ThompsonSep 5, 2025
    How to fix ARC- FAULT (1041 DATA:0000) on SOLIS Inverter?
    • B
      Brenda MorganSep 5, 2025
      If your SOLIS Inverter displays 'ARC- FAULT (1041 DATA:0000)', it means there is an AFCI failure. Check that all connections within your PV system are tight. If further adjustment is needed, arc fault settings can be changed in advanced settings.
  • J
    James WrightSep 17, 2025
    What does 'OV-Vbatt-H' mean on my SOLIS S5-EH1P5K-L and how do I troubleshoot it?
    • J
      Jose CobbSep 17, 2025
      If your SOLIS Inverter displays 'OV-Vbatt-H', check the battery circuit for any jumps. You can also try restarting the inverter.
  • A
    austinalisonAug 30, 2025
    How to fix IGBT-OV-I (1048 DATA:0000) error on SOLIS S5-EH1P5K-L Inverter?
    • A
      Amy BowersAug 30, 2025
      If your SOLIS Inverter shows 'IGBT-OV-I (1048 DATA:0000)', which means there is an IGBT overcurrent, try restarting the system and see if the error clears.

SOLIS S5-EH1P5K-L Specifications

General IconGeneral
ModelS5-EH1P5K-L
TypeHybrid Inverter
Rated Output Power5kW
Max. PV Input Voltage600 V
Start Voltage120 V
Number of MPPTs2
Max. AC Apparent Power5.5kVA
Max. AC Output Power5kW
Nominal AC Voltage230 V
AC Voltage Range180-280V
Nominal Grid Frequency50/60Hz
THDi<3%
DC SwitchYes
Protection DegreeIP65
Operating Temperature Range-25°C to +60°C
Max. Charging/Discharging Power5kW
Battery TypeLithium-ion
CoolingNatural Convection
MPPT Range90 V - 520 V
MPPT Voltage Range90 V - 520 V
Peak Power5500 W
Noise<25 dBA
CommunicationWiFi/GPRS