EasyManua.ls Logo

SOLIS S5-GC125K-HV User Manual

SOLIS S5-GC125K-HV
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation and Operation Manual
Solis Three Phase Inverter
(100-125)K
Ginlong Technologies Co., Ltd.
Ginlong Technologies Co., Ltd.
No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo,
Zhejiang, 315712, P.R.China.
Tel: +86 (0)574 6578 1806
Fax: +86 (0)574 6578 1606
If you encounter any problem on the inverter, please find out the inverter S/N
and contact us, we will try to respond to your question ASAP.
Please adhere to the actual products in case of any discrepancies in this user manual.
Ver1.7

Table of Contents

Questions and Answers:

SOLIS S5-GC125K-HV Specifications

General IconGeneral
ModelS5-GC125K-HV
Rated Power125 kW
Max. DC Input Power187.5 kW
Max. Input Voltage1100 V
Start-up Voltage250 V
MPPT Voltage Range200-1000V
Number of MPPTs10
Rated AC Output Power125 kW
Max. AC Apparent Power137.5 kVA
Rated Grid Voltage400V
Grid Voltage Range320-480V
Rated Grid Frequency50/60 Hz
Grid Frequency Range45-55 Hz / 55-65 Hz
Power Factor0.8 leading to 0.8 lagging
THDi<3%
DC SwitchYes
Cooling MethodForced air cooling
Protection DegreeIP66
Weight86 kg
Efficiency98.7%
Maximum DC Input Power187.5 kW
Maximum DC Input Voltage1100 V
Maximum Input Current per MPPT26 A
AC Nominal Voltage400V
AC Output Frequency50/60 Hz
Maximum Efficiency98.7%
European Efficiency98.4%
Ingress Protection RatingIP66
ProtectionDC reverse polarity, AC overcurrent, grid monitoring
Operating Temperature Range-25°C to +60°C
CommunicationRS485, Ethernet
Communication InterfaceRS485, Ethernet

Summary

Introduction

1.1 Product Description

Describes the Solis Three Phase Inverters and their function.

Safety Instructions

2.1 Safety Symbols

Explains symbols used for safety warnings.

2.2 General Safety Instructions

Provides essential safety guidelines for installation and use.

Installation

3.3 Mounting the Inverter

General information on mounting the inverter to walls or racks.

3.3.1 Wall mounting

Step-by-step instructions for wall mounting the inverter.

3.3.2 Rack mounting

Step-by-step instructions for rack mounting the inverter.

3.4 Electrical Connections

Overview of all electrical connection types for the inverter.

3.4.1 Grounding

Procedures for correctly grounding the inverter.

3.4.2 Connect PV side of inverter

Steps for connecting the DC input from the PV array.

3.4.3 Connect grid side of inverter

Instructions for connecting the inverter to the AC grid.

Commissioning

5.1 Selecting the appropriate grid standard

Verifying and setting the correct grid standard.

5.1.1 Verifying grid standard for country of installation

Procedure to confirm the grid standard.

5.2 Changing the grid standard

Overview of how to change grid standard settings.

5.2.1 Procedure to set the grid standard

Step-by-step guide to setting the grid standard.

5.4 Preliminary checks

Verifying DC, AC connections and configuration before operation.

Start and Shutdown

6.1 Start-up procedure

Step-by-step guide to safely start the inverter.

6.2 Shutdown procedure

Step-by-step guide to safely shut down the inverter.

Normal operation

7.5 Advanced Settings - Technicians Only

Technical settings for advanced users and maintenance.

7.5.1 Selecting Standard

Function to select the grid's reference standard.

Troubleshooting

9. Troubleshooting

Lists common alarm messages, failure descriptions, and solutions.

Specifications

Solis-100K-5G Specifications

Detailed technical specifications for the 100K-5G model.

Solis-110K-5G Specifications

Detailed technical specifications for the 110K-5G model.

Solis-125K-HV-5G Specifications

Detailed technical specifications for the 125K-HV-5G model.