What to do if Solplanet ASW LT Inverter displays E61 E62 error?
- JJennifer SimonSep 23, 2025
If your Solplanet Inverter is showing E61 or E62 errors, check the DRED device communication or operation.
What to do if Solplanet ASW LT Inverter displays E61 E62 error?
If your Solplanet Inverter is showing E61 or E62 errors, check the DRED device communication or operation.
What to do if Solplanet ASW LT Inverter displays error E35?
If your Solplanet Inverter is showing error E35, you should check the fuse and the circuit breaker in the distribution box. Verify the grid voltage and usability, and inspect the AC cable and grid connection on the inverter. If the problem continues, it is recommended to contact the service.
Why does my Solplanet ASW LT show error E38?
If your Solplanet Inverter shows error E38, check the PV array’s insulation to ground, ensuring the insulation resistance to ground is greater than 1 MOhm. Perform a visual inspection of all PV cables and modules. Also, make sure the grounding connection of the inverter is reliable. If the fault occurs often, it is recommended to contact the service.
How to fix Solplanet ASW LT Inverter error E36?
To address error E36 on your Solplanet Inverter, ensure the grounding connection of the inverter is reliable. Perform a visual inspection of all PV cables and modules. If the error persists, it is recommended to contact the service.
What to do if Solplanet ASW LT Inverter shows error E37?
If your Solplanet Inverter is displaying error E37, check the open-circuit voltages of the strings, ensuring they are below the maximum DC input voltage of the inverter. If the input voltage is within the permitted range and the error continues, it is recommended to contact service.
What to do if Solplanet ASW LT displays E48 error?
If your Solplanet Inverter displays an E48 error, check whether the electric supply is abnormal. If the electric supply is normal and this fault still exists, please contact the service personnel.
What to do if Solplanet ASW LT displays E65 error?
If your Solplanet Inverter displays an E65 error, make sure the grounding connection of the inverter is reliable. If this fault occurs often, contact the service.
What to do if Solplanet Inverter displays E46 error?
If your Solplanet Inverter displays an E46 error, check whether the open circuit voltage of each photovoltaic group is ?1020V. If the open circuit voltage of each PV group is less than 995V and this fault still exists, please contact the service personnel.
What to do if Solplanet ASW LT displays E38 error?
If your Solplanet Inverter displays an E38 error, check the PV array’s insulation to ground, ensuring that the insulation resistance to ground is greater than 1 MOhm. Perform a visual inspection of all PV cables and modules. Also, ensure the grounding connection of the inverter is reliable. If the fault frequently occurs, contact the service.
What to do if Solplanet ASW LT Inverter shows E34 error?
If your Solplanet Inverter displays an E34 error, first check the grid voltage and the grid connection on the inverter. Verify the grid voltage at the inverter's connection point. If the grid voltage is outside the permissible range due to local grid conditions, consider adjusting the monitored operational limits after consulting with your electric utility company. If the grid voltage is within the permitted range and the error persists, contact service.
Provides general information about the ASW LT-G2-Pro series inverter.
Specifies the inverters covered by this manual.
Defines the intended audience and explains safety symbols used in the manual.
Details the proper intended applications and operational constraints for the inverter.
Outlines critical safety precautions regarding electric shock and high voltages.
Explains various safety symbols found on the inverter's product label.
Lists the components included in the inverter package.
Procedure for inspecting the inverter for damage incurred during shipping.
Details safe mounting locations, clearances, and environmental conditions.
Step-by-step guide for physically installing the inverter on a wall.
Critical safety guidelines for electrical connections, emphasizing high voltage risks.
Identifies and describes all connection ports on the inverter.
Illustrates wiring diagrams and covers AC connection requirements.
Details the procedure for connecting the inverter to the power grid.
Details DC connection requirements and connector assembly/disassembly.
Procedure for connecting the PV array, including safety notices.
Covers the connection of external communication devices like WiFi or 4G sticks.
How to monitor the inverter system using WLAN.
Active power control with smart meters and remote firmware updates.
DRED control, third-party device communication, and earth fault alarms.
Essential electrical and mechanical checks before inverter operation.
Setting safety codes and the step-by-step inverter start-up process.
Overview of the inverter's control panel.
Explanation of LED indicator functions.
Detailed technical specifications for DC input parameters across models.
Technical specifications for AC output parameters across models.
General data, safety regulations, and tools/torque specifications.
Lists error codes (E33-E65, Permanent Faults) and their solutions.
Lists warning codes and their corresponding messages for system monitoring.
Instructions for cleaning DC switch contacts and heat sink.
| Protection Rating | IP65 |
|---|---|
| Cooling Method | Natural Convection |
| Nominal AC Voltage | 230 V |
| Operating Temperature Range | -25°C ~ +60°C |
| Communication Interfaces | RS485, WiFi, Ethernet |