J4 WT Protect Drive
Full installation guide
[ Click here to return to contents ]
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
Non contractual images.
3.4. TECHNICAL DATA
LIMIT SWITCH CAPACITY
The drive is supplied in its lower end limit position. The upper end limit
position is pre-set at 120 turns of the drive sha above the lower end
limit position.
THERMAL CUTOUT
The drive is protected against overheating by a thermal cut-out. In the
event of heating caused by prolonged use, the drive will stop for a few
minutes.
DIRECTION OF ROTATION
Lower end limit position
0 turns
120 turns
Factory setting:
Upper end limit position
Max. 200 turns
Direction of rotation subject to the correct positioning of
the drive in the application and correct wiring (see section
4.3 Installing the drive).
The direction of rotation is also engraved on the drive housing.
Up
Down