Copyright © 2010 Somfy SAS. All rights reserved.
Sunilus io / Sunilus screen io
5
EN
5.4. Adjusting the end limits
The upper and lower end limits must be set.
Setting the upper end limit
Set the awning to the upper end limit.1)
Press and hold the Up button for > 2 seconds to raise
the awning in one continuous movement.
Stop the awning in the desired position.
2)
If necessary, adjust the position of the awning using the 3)
Up or Down buttons.
Press the “my” and Down buttons simultaneously: the
4)
awning is lowered in one continuous movement even after
the “my” and Down buttons have been released.
At the halfway point, briey press the “my” button to
5)
stop the awning and go to the following step.
Setting the lower end limit
Set the awning to the lower end limit.1)
Press and hold the Down button for > 2 seconds to
lower the awning in one continuous movement.
Stop the awning in the desired position.
2)
If necessary, adjust the position of the awning using the 3)
Up or Down buttons.
Press the “my” and Up buttons simultaneously: the
4)
awning is raised in one continuous movement even after
the “my” and Up buttons have been released.
At the halfway point, briey press the “my” button to
5)
stop the awning.
Press the “my” button again until the awning makes a
6)
movement: the end limits have been programmed. Go
to chapter “Programming the rst Somfy io local control
point”.
5.5. Programming the rst Somfy io local control point
5.5.1. Using the pre-programmed Somfy io local control point
Briey press the PROG button on this control point (G): the -
awning makes a brief movement, and the control point has
been programmed.
5.5.2. After a single power outage
Press the Up and Down buttons simultaneously on 1)
this new control point (H) until the awning makes a
movement.
Briey press the PROG button on this control point (H):
2)
the awning makes a brief movement, and the control point
has been programmed.
5.6. Checking the settings
Check the setting of the upper and lower end limits using the Somfy io local control point. -
1
3
5
2
4
Go to the following
step.
1
3
5
2
4
6
prog. g
2
prog. hh
1
5065925X00_Sunilus_io.indb 5 16/02/10 11:01:04