69
Program Manager.
e) Make sure the zone is set up in the software.
No Paging signal in zones. a) Be sure Paging audio source is connected to the
Page IN jack on the Primary DAB Controller.
b) Be sure Page IN/OUT are connected in an
expanded system (multiple DAB Controllers).
c) Be sure 12V Page Trigger input is connected.
d) Be sure Page Trigger device is outputting 6-12V
AC/DC.
No audio in Zones driven by secondary DAB
Controllers in an expanded system.
a) Be sure the Source Outputs on the Primary DAB
Controller (the one that has the source
components connected to it) are connected to the
Source Inputs on the Secondary Controller(s).
b) Check Volume Offset for Sources on Secondary
Controller(s) in Program Manager. (Should be
‘0’.)
External Amplifiers
Keypad or Remote volume up/down commands
change volume in all sub-zones when using
external multi-channel amplifier for sub-zone
expansion.
Be sure the specific Zone variable/fixed output
switch is in the fixed (in) position. Also be sure the
Zone volume is set it’s appropriate maximum
volume in Program Manager to achieve proper
audio level in sub-zones.
Keypad or Remote volume up/down commands
do not adjust volume when using a external
amplifier.
Be sure the specific zone variable/fixed output
switch is in the variable (out) position.
Infrared Control
Remote controls from other products do not get
controlled through local IR.
On the rear panel move the front IR pass switch to
on.
IR commands are not being routed to specific
source components.
a) Emitters must be plugged into Programmed IR
jacks.
b) IR commands must be programmed to output
from a specific port in Macro Editor.
c) Programmed IR cannot be used in expanded
systems (multiple DAB Controllers.)
No IR output at Primary DAB Controller from
Keypad button presses connected to Secondary
Controller(s) in an expanded system (multiple
DAB Controllers).
IR Link(s) must be connected in parallel. A system
with more than two controllers must have a
1N4002 diode in series with the signal line to out
to ‘steer’ the IR signals to the primary controller.
DAB1 remote does not control the DAB1. a) In Program Manager, select Device>General
Setup, be sure the Zone to be controlled from the
front panel of the DAB Controller is selected.
b) Remove the batteries, wait about 10 seconds and
reinstall the batteries. Use only alkaline batteries.
Also try to keep the remote off static surfaces like
carpet, rugs.
DAB1 Remote does not control source
components.
a) Check to make sure the IR emitters are attached
over the IR eyes on the front of the source
components and properly plugged in to the
DAB1.
b) Be sure IR commands for source components
have been associated to DAB Remote
commands (Stop, Play, Pause, Skip Rev, Skip
Fwd) by source, by zone in Program Manager.
Source does not respond to IR command output
by DAB Controller
a) Check Program Manager to be sure the proper
command has been programmed to a button.