13Instruction for use | Superaqua 1
6.7 Event and error messages
If an event or error occurs in the counter, this is indicated by a message on the display. The
display of the event message is included in the display loop for 1 second. The events 01 to 06
and 08 are additionally transmitted in the radio telegram.
6.8 Battery life time
To indicate the end of the device life, the battery warning symbol is activated in the display
(permanent display) and the error message Err 02 is set. This occurs in a time-controlled manner
when the "Time to battery warning symbol" stored in the device for this purpose has expired.
This warning symbol is also displayed in addition with error Err02 in the event of an unexpected
earlier voltage drop of the battery.
Attention. The device must be replaced
Overview of event and error messages
For various analyses it is very helpful to examine the chronological course of events. To make this possible, a rolling event
log with max. 10 entries is integrated in the water mete: If many temporary events occur in succession, older important
messages may fall out.
Code Message Actions
Standard
LCD Display
Standard radio
information
Err01 Systeme error Replace device Yes Yes
Err02 Low battery Replace device Yes Yes
InF03 Manipulation Water meter no longer valid for billing No Yes
InF04 Radio error Check device Yes Yes
InF05 Pipe rupture Check pipe network Yes Yes
InF06 Leakage Check pipe network for leaks Yes Yes
InF07 Qmax-Error Check water meter and pipe network No No
InF08 Backow error Check water meter installation No Yes
InF10 No ow Check pipe network Yes Yes
Err09 End of device life reached Replace device Yes Yes