Manual Supercom 636 R+W rev. 010312 26
10. Annex E
10.1 Add entry to device list to write a device
Manufacturer ID
Generation of
Meter
Measured Media
Radio Address
Radio Device Type
Options
Application Reset
Subcode
Date of Last
Successful Reading
Bytes 4 2 1 1 4 1 1 1 1 2
Notes a, e a, e a a b, e b b b b c, e
Device type Values to write
Set of values xxxxxxxxh 4DEEh 4 08h xxxxxxxxh 0 00h 00h 00h 0101h
Set of values xxxxxxxxh 4DEEh 1 00h xxxxxxxxh 2 00h 00h 00h 0101h
Set of values xxxxxxxxh 4DEEh 12 04h xxxxxxxxh 3 00h 00h 00h 0101h
Set of values xxxxxxxxh 4DEEh 4 04h xxxxxxxxh 1 00h 00h 00h 0101h
Set of values xxxxxxxxh 38AFh 4 07h xxxxxxxxh 4 01h 00h 00h 0101h
Set of values xxxxxxxxh 4DEEh 10 07h xxxxxxxxh 4 00h 00h 00h 0101h
Set of values xxxxxxxxh 4DEEh 20 07h xxxxxxxxh 4 00h 00h 00h 0101h
Set of values xxxxxxxxh 4DEEh 16 08h xxxxxxxxh 5 31h 00h 00h 0101h
541 pulses Set of values xxxxxxxxh 4DEEh 10 00h xxxxxxxxh 6 10h 00h 00h 0101h
Notes
a This value is part of the M-Bus secondary address used to access the data of a device stored in 636.
It is updated by 636 according to the value really read from the device by radio.
b This value is used to access the device by radio. It is never modified by the 636 itself.
c The date 1.1.2000 means ""not yet successful read"", coded in M-Bus G type: 0101h
e Multibytes values are transmitted with LSB first.
Options
bit7..0 Internal use
10.2 Writing standard products
Field
Frame bytes in hex (Note 1) Coding Comment
Star t, Length
68,Le Le,68
Control
73|53
Send user data to slave, SND_UD
Control Information
51
Stuctured write telegram
See product documentation
To write a standard product (e.g.580, 581, 590, 541, 539) send a standard command āSND_UDā
as described in the respective M-Bus frames documentation.