56
Chapter 2 Menu
[C8] EXTEND menu
Enter the password (ENTER PASSWORD [C81])
When the correct password is entered, the following
item appears. Choose the function to execute.
RE-LOAD FACTORY DATA... : Restore factory
default data for the board installed in the selected
slot. ÷[C811]
MEMORY CARD... : Read and write setting and
adjustment data by using the monitor memory
card. ÷[C812]
RE-START MONITOR: Restart the monitor.
÷[C813]
ADJ INT SIGNAL: Automatically adjust the SETUP
level and 100 IRE level of internal signals.
÷[C814]
VDR MODE: Select the mode of the connected VCR.
÷[C815]
MAINTENANCE: Display the menu for
maintenance.÷[C816]
[C811] RE-LOAD FACTORY DATA menu
Select a slot where a board is installed to reload
factory default data to the board.÷[C8111]
[C8111] RE-LOAD FACTORY DATA menu
The following message appears to confirm the data
reload operation.
DATA RESET TO
ITS FACTORY SETTING
AND MONITOR WILL RESTART
ARE YOU SURE?
OK: ENTER KEY
CANCEL: MENU KEY
OK: To continue, press the ENTER or Ent button.
÷ Resets the data and automatically turn the
monitor off and on again.
CANCEL: To cancel, press the MENU button.
÷ Returns to the RE-LOAD FACTORY DATA
menu. ([C811])
[C812] MEMORY CARD menu
Insert the monitor memory card into the MEMORY
CARD slot and select the operation to perform.
BACK UP SYSTEM DATA... : Write the data to the
monitor memory card. ÷[C8121]
RE-STORE SYSTEM DATA... : Read the data from
the monitor memory card. ÷[C8122]
Notes
Before using a monitor memory card, it must be
formatted it with the FORMAT menu ([D4]).
System data and MEMORY CARD data ([D]) cannot
be stored on the same memory card. To store memory
card data, use another memory card.
The BKM-12Y monitor memory card has a capacity
of 256 Kbytes. It can store either system data for up to
8 monitors or 38 files of memory card data.
The input signal is not displayed during the data
saving or loading.
[C8121] BACK UP SYSTEM DATA menu
While the system is writing the data, a “–” mark blinks
at the top right of the menu. (It takes some time to save
the data.)
BACK UP SYSTEM DATA
IN PROGRESS...SYSTEM
[C8122] RE-STORE SYSTEM DATA menu
The following message appears to confirm the data
restore operation.
RE-STORE SYSTEM DATA
ALL DATA WILL BE RESTORED
ARE YOU SURE?
OK: ENTER KEY
CANCEL: MENU KEY
OK: To continue, press the ENTER or Ent button.
÷ Read the data from the monitor memory card
and automatically turn the monitor off and on
again.
CANCEL: To cancel, press the MENU button.
÷ Return to the MEMORY CARD menu ([C812]).
[C813] RE-START MONITOR menu
Turn the monitor off and on again automatically.
[C814] ADJ INT SIGNAL menu
Adjust the SETUP level and 100 IRE level of the
internal white signal which is used with the COLOR
TEMP ADJ menu ([B]).
[C815] VCR MODE menu
Improve the skew of the picture when a non-standard
signal is input from the connected VCR. This menu is
effective for the 480/60I or 575/50I format signals only.
ON: Always activates this function for the 480/60I or
575/60I format signals.
OFF: Deactivates this function.
[C816] MAINTENANCE menu
The menu for the maintenance personnel is displayed.
[C8] Using Extended Functions (SET UP 8) — EXTEND Menu

Table of Contents