17
CDX-GT800D/GT805DX
SECTION 3
DIAGNOSIS FUNCTION
Description of the Diagnostics function:
1. Setting the Diag display mode
With the power off, press the [4] button, [5] button, and [4] button
on the set body or the remote control (for more than 2 seconds)
in turn.
2. Canceling the Diag display mode
During the Diag function mode, press the [OFF] button.
3. Initial display in the Diag display mode.
Just when the Diag mode is entered, “reset count” is displayed.
The display mode is switched by each rotation of SEEK + >
/ . SEEK --- dial.
4. Contents of each display mode
4-1. Reset count display mode
4-2. Reset count by watchdog timer display mode
4-3. Number of connected units display mode
The display mode is switched by push of [PUSH ENTER] button
during the number of connected units display mode.
.
4-4. Operating hours display mode
Reset count display
OFFSET/FAILURE error display
CD error information display
Operating hours display
Number of connected units display
Reset count by watchdog timer display
01 XX
DIAG
02 XX
DIAG
03 1 XXX
DIAG
04 XXXX
DIAG
05 1 XX
DIAG
06 1XXXXX
DIAG
Reset count
(in hexadecimal format)
Diag code
01: Reset count
01 XX
DIAG
Reset count
(in hexadecimal format)
Diag code
02: Number of resets by watchdog timer
02 XX
DIAG
Show the number of connected units for
CD-C, MD-C and XM respectively from
the rightmost (in hexadecimal format).
Recency of information
1-3: 1 represents the latest.
Diag code
03: Number of connected unit.
03 Y XXX
DIAG
No. of connected units history 1 (latest) display
No. of connected units history 3 display
No. of connected units history 2 display
03 1 XXX
DIAG
03 2 XXX
DIAG
03 3 XXX
DIAG
Operating hours
(in hexadecimal format)
Diag code
04: Operating hours
04 XXXX
DIAG