CFD-RG880CP
22
TAPE SECTION
0 dB = 0.775V
1. Demagnetize the record/playback head with a head demagne-
tizer.
2. Do not use a magnetized screwdriver for the adjustments.
• Test Tape
Tape Signal Used for
P-4-A063 6.3 kHz, –10 dB Azimuth Adjustment
WS-48A 3 kHz, 0 dB Tape Speed Adjustment
Tape Speed Adjustment
Procedure:
Mode: playback
Adjust so that the value on the digital frequency counter is 3,000
Hz.
Specifi cation Value:
Digital frequency counter
2,940 to 3,060 Hz
Adjust so that the frequency at the beginning and that at the end of
tape winding are between 2,970 to 3,030 Hz.
Jjack (J391)
set
32 Ω
test tape
WS-48A
(3 kHz, 0 dB)
digital frequency
counter
Tape speed adjustment
control inside motor
(M971)
Adjustment Location: