CFD-RG880CP
23
TUNER SECTION
0 dB = 1 μV
• AM Section
Setting:
RADIO BAND•AUTO PRESET button: AM
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
Output level:
as low as possible
Put the loop
antenna close to
the set.
+
level meter
set
32 Ω
J jack (J391)
• FM Section
Setting:
RADIO BAND•AUTO PRESET button: FM
FM RF signal
generator
75 kHz frequency
deviation by 1 kHz
signal
Output level:
as low as possible
+
level meter
set
32 Ω
0.01 μF
TUNER board
TP (GND)
TUNER board
TP-ANT(JW2)
J jack (J391)
digital voltmeter
TP (CV)
TP (GND)
100 k Ω
TUNER board
Repeat the procedures in each adjustment several times, and
the tracking adjustments should be nally done by the trimmer
capacitors.
Remove FM antenna in FM adjustment.
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T1
450 kHz
AM FREQUENCY COVERAGE ADJUSTMENT (EXCEPT MX)
Frequency Display 531 kHz 1,611 kHz
Reading on Digital voltmeter 1.0 ± 0.05 V 4.8 ± 0.6 V
Adjustment Part L4 <con rmation>
AM FREQUENCY COVERAGE ADJUSTMENT (MX)
Frequency Display 530 kHz 1,710 kHz
Reading on Digital voltmeter 1.0 ± 0.05 V 5.2 ± 0.7 V
Adjustment Part L4 <con rmation>
AM TRACKING ADJUSTMENT (EXCEPT MX)
Adjust for a maximum reading on level meter.
L3 CT3
621 kHz 1,404 kHz
AM TRACKING ADJUSTMENT (MX)
Adjust for a maximum reading on level meter.
L3 CT3
620 kHz 1,400 kHz
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
T2
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Frequency Display 87.5 MHz 108 MHz
Reading on Digital voltmeter 1.3 ± 0.3 V 3.0 ± 0.2 V
Adjustment Part <con rmation> L2
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1 CT1
87.5 MHz 108 MHz
• Abbreviation
MX : Mexican model
Adjustment Location: See page 24.