8. Changer Mecha Check
On this test mode screen, selecting [8] enables the table sensor
and the disc sensor adjustment. The following screen appears.
Display when [8] is selected in the Drive Manual Operation
## Changer Mecha Check ##
ENTER : Mecha Initial
OP/CL : Disc Load/UnLoad
jogFOR : Table R StepTurn
jogPRV : Table L StepTurn
PLAY : Table Rotate
PAUSE : Mecha Adjust
DISP : Sensor Status
_
RETURN : Exit
All operations are the same as those of the Changer Manual Move
except [OP/CL], [PLAY] and [PAUSE].
[OP/CL] : Loads the disc from the chucking position
Disc Load/UnLoad of the T.table toward inside the MD or from
inside the MD to the T.table.
When the Disc Load is selected a series of
operation starting from Door Close – T.table
Rotate – Chucking is performed.
When the Disc UnLoad is selected a series
of operation starting from Unchucking –
T.table Rotate – Door Open is performed.
[PLAY] : Enters the Disc Sensor Adjustment Mode.
Table Rotate (Refer to the “5. Mechanical Adjustments”
(page 45))
The 400CHG Table Rotate appears on the
screen.
[PAUSE] : Enters the Table Sensor Adjustment Mode.
Mecha Adjust (Refer to the “5. Mechanical Adjustments”
(page 45))
The 400CHG Mecha Adjust appears on the
screen.
Display when [PLAY] is selected in the Changer Mecha Check.
## 400CHG Table Rotate ##
RIGHT : Turn Right
LEFT : Turn Left
Table 1/2/3/4 : X/X/X/X
Disc Sensor : XXX
RETURN : Exit
[RIGHT] : Rotates T.table anti clock wise.
Turn Right
[LEFT] : Rotates T.table clock wise.
Turn Left
Table 1/2/3/4 : These items are the same as those of the
Disc Sensor 400CHG Sensor Check.
Display when [PAUSE] is selected in the Changer Mecha Check.
## 400CHG Mecha Adjust ##
UP : Load in
DOWN : Load out
RIGHT : Pop Up
LEFT : Pop Down
Table 1/2/3/4 : X/X/X/X
RETURN : Exit
[UP] : Loads the disc from the chucking position
Load in of the T.table toward inside the MD during
pressing [UP].
[DOWN] : Loads the disc from inside the MD to the
Load out T.table during pressing [DOWN].
[RIGHT] :Pops up the lever.
Pop Up
[LEFT] :Pops down the lever.
Pop Down