43
Command List
Command List (6/6)
Command Set Command Command Packet Comments
CAM_MD On 8x 01 04 1B 02 FF Motion Detection On/Off
Off 8x 01 04 1B 03 FF
Function Set 8x 01 04 1C 0m 0n 0p 0q 0r 0s FF m: Display mode
n: Detection Frame Set (0 to F)
pq: Threshold Level (00 to FF)
rs: Interval Time set (00 to FF)
Window Set 8x 01 04 1D 0m 0p 0q 0r 0s FF m: Select Detection Frame (0, 1, 2, 3)
p: Start Horizontal Position (00 to 0B)
q: Start Vertical Position (00 to 07)
r: Stop Horizontal Position (01 to 0C)
s: Stop Vertical Position (01 to 08)
Alarm (Reply) y0 07 04 1B 0p FF p: Detection Frame Number
CAM_Continuous On 8x 01 04 69 02 FF ZoomPosition data Continuous Output On/Off
ZoomPosReply Off 8x 01 04 69 03 FF
(Reply) y0 07 04 69 0p 0p 0q 0q 0q 0q FF pp: D-Zoom Position
* 00: When Zoom Mode is Combine
qqqq: Zoom Position
CAM_ 8x 01 04 6A 00 00 0p 0p FF pp: Interval Time [Vertical timing]
ReplyIntervalTimeSet
CAM_RegisterValue 8x 01 04 24 mm 0p 0p FF mm: Register No. (=00-7F)
pp: Register Value (=00-7F)
CAM_ColorEnhance Parameter Set 8x 01 04 20 mm nn mm: Threshold level
pp qq rr ss tt uu FF nn: Hysteresis width
pp: Fixed color Y of high-intensity side
qq: Fixed color Cr of high-intensity side
rr: Fixed color Cb of high-intensity side
ss: Fixed color Y of low-intensity side
tt: Fixed color Cr of low-intensity side
uu: Fixed color Cb of low-intensity side
* Set 00h to 7Fh for each parameter.
On 8x 01 04 50 02 FF Color Enhancement ON/OFF
Off 8x 01 04 50 03 FF

Related product manuals