SECTION
3
ELECTRICAL
ADJUSTMENTS
©
This
adjustment
should
be
executed
after
MW
band
adjustment
3-1.
RADIO
SECTION
@FM
Section
Setting
:
BAND
switch:
FM
FM
¢f
signal
generator
22.5kHz
frequency
deviation
by
400Hz
signal
output
level
:
as
low
as
possible
telescopic
antenna
input
«
MW/LW
Section
Setting
:
BAND
switch
:
MW/LW
AM
ff
signal
generator
Put
the
lead-wire
antenna
close
to
the
set.
(qa
30%
amplitude
modulation
by
400Hz
signal
output
level
:
as
low
as
possible
*
SW
Section
Setting
:
BAND
switch
:
SW1—SW9
AM
ff
signal
generator
30%
amplitude
modulation
by
400Hz
signal
output
level
:
as
low
as
possible
telescopic
antenna
input
VTVM
(range:
0.5—5V
ac)
Phones
jack
@
Repeat
the
procedures
in
each
adjustment
several
times,
and
the
frequency
coverage
and
tracking
adjustments
should
be
finally
done
by
the
trimmer
capacitors.
is
completed
because
the
LW
and
SW
bands
use
the
BAR
ANT
and
CV1
in
common
with
the
MW
band.
Therefore,
if
MW
band
is
adjusted,
the
LW
and
SW
bands
must
also
be
readjusted.
FM
FREQUENCY
COVERAGE
ADJUSTMENT
Adjust
for
a
maximum
reading
on
VT
VM.
87.3MHz
108.3MHz
MW
FREQUENCY
COVERAGE
ADJUSTMENT
Adjust
for
a
maximum
reading
on
VTVM.
520kHz
1.650kHz
AM
IF
ADJUSTMENT
Adjust
for
a
maximum
reading
on
VT
VM.
Tl
455kHz
ADJUSTMENT
©
Preparation
for
SW
band
adjustment
After
making
sure
that
the
MW
band
adjustment
has
completed,
set
the
pointer
to
the
center
of
character
of
6.0,
7.2,
11.8
or
21.6MHz
which
is
reference
position
of
dial
character,
and
fix
the
CV1
at
this
position.