EasyManua.ls Logo

Sony ICP-3000 - 1 Installation; Operating Environment; Power Supply

Sony ICP-3000
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-1 (E)
ICP-6520/6530/3000/6511
Section 1
Installation
1-1. Operating Environment
Operating guaranteed temperature: +5 dC to +40 dC
Performance guaranteed temperature: +10 dC to +35 dC
Operating humidity: 10 % to 90 %
Storage temperature: _20 dC to +60 dC
Mass
ICP-6520: Approx. 14.5 kg
ICP-6530: Approx. 20 kg
ICP-3000: Approx. 15 kg
ICP-6511: Approx. 2.3 kg
Prohibited locations for installation
. Areas where the unit will be exposed do direct sunlight
or any other strong lights.
. Dusty areas
. Areas subject to vibration.
. Areas with strong electric or magnetic fields.
. Areas near heat sources.
. Areas where is subject to electrical noise.
. Areas subject to static electricity.
Ventilation
The inside of the ICP-6520/6530/3000 is cooled by a fan.
The power supply can be damaged if the exhaust vent (side
on the right) and air intake (side on the left) are blocked or
the fan is stopped. (Refer to the air flow illustration of
“Fan” in Section 2-2-2.) Ensure a distance of 10 cm or
more from the air intake and exhaust vent.
1-2. Power Supply
1. Power specifications
A switching regulator is used for the power supply of
ICP-6520/6530/3000. A voltage within the range of 100 V
to 240 V can be used without changing the supply voltage.
Power requirements: AC 100 to 240 V, 10 %
Power frequency: 50/60 Hz
Current consumption: ICP-6520/6530/3000: Maximum 1.1A
n
As the inrush current flows at turn-on, the capacity of the
AC power source must be commensurate with this load.
If the capacity of the AC power is not adequately large, the
AC power source breaker will operate or the unit will
abnormally operate.
Maximum inrush current
ICP-6520: 44 A peak, 10 A r.m.s. (240 V AC)
ICP-6530: 46 A peak, 11 A r.m.s. (240 V AC)
ICP-3000: 40 A peak, 10 A r.m.s. (240 V AC)
ICP-6511: 57 A peak, 8 A r.m.s. (240 V AC)
2. Power cord
This unit does not come with a power cord.
To get a power cord, please contact your local Sony Sales
Office/Service Center.
w
. Use the approved Power Cord (3-core mains lead)/Appli-
ance Connector/Plug with earthing-contacts that con-
forms to the safety regulations of each country if appli-
cable.
. Use the Power Cord (3-core mains lead)/Appliance
Connector/Plug conforming to the proper ratings (Volt-
age, Ampere).
If you have questions on the use of the above Power Cord/
Appliance Connector/Plug, please contact your local Sony
Sales Office/Service Center.
w
. Never use an injured power cord.
. Plugging the power cord in the AC inlet, push as far as it
will go.
Specified power cord
For ICP-6520/6530/3000
For customers in the U.S.A. and Canada
1 Power cord, 125 V 0 A (2.4 m) : ! 1-551-812-31
AC inlet
1
For customers in the all European countries
1 Power cord, 250 V 10 A (2.5 m) : ! 1-782-929-12
1
AC inlet

Other manuals for Sony ICP-3000