1-6
MVS-8000X/7000X
1-4-1.  Installing the Plug-in Boards
c
Be sure to turn off the POWER switch before starting 
installation work.
If installation work is started with the POWER switch left 
on, it may cause electrical shock or damage to printed 
circuit boards.
Each plug-in board of the Production Switcher Processor 
MVS-8000X/MVS-7000X is allocated to a specifi c slot 
into which they must be installed. Check to see that the 
respective plug-in boards are installed in their respective 
slots.
The name of the board is shown near the eject lever at the 
right-most end of each plug-in board.
Names of the plug-in boards and the slot numbers, to which 
the plug-in boards are allocated, are shown on the
Extract PWB stopper assembly inside the front panel of the 
MVS-8000X Install the respective plug-in boards accord-
ing to this instruction.
c
.  Check to see that connectors of the plug-in boards are 
securely inserted into the mother board (MVS-8000X: 
MB-1150 board, MVS-7000X: MB-1151 board) without 
loose contact.
  If any plug-in board is inserted into the incorrect slot, it 
causes a system error and the system will not work 
correctly.
.  After installing the plug-in board, the software must be 
installed. Install the software same version as the MVS-
8000X/MVS-7000X.
  For installing the software, refer to the user’s guide of 
the MVS-8000X/MVS-7000X system.
Installation Procedure
1.  Turn off the main power of this unit (MVS-8000X) 
and disconnect the AC power cord from the wall outlet.
2.  Loosen the four screws (with drop-safe) and remove 
the front panel to the arrow.
Front panel
Screw (with
drop-safe)
This figure shows MVS-8000X
Screw (with
drop-safe)
3.  Push the black panel lock toward the (1) direction to 
unlock, pull the knob toward the (2) direction an 
remove the blank panel.
  n
  Store the removed blank panel in a safe place.
Blank panel
Lock
Knob
2
1
This figure shows MVS-8000X