44
Settings on the RM Configuration Menu
IRIS
AUTO
RANGE
9
OFF , On
Selects if the minimum and maximum
values of the adjustment range of the
IRIS control in Absolute mode are to be
set automatically according to the lens
file data.
OFF:The iris is adjusted within the
values set with IRIS MIN and IRIS
MAX items on this Detail menu.
ON: The iris is automatically adjusted
according to the lens file data of
the camera (effective only with a
camera equipped with an
automatic detection facility).
IRIS MIN 10
CLS , 22.9 - 1.0
Sets the minimum adjustment value (f) of
the IRIS control in Absolute mode.
CLS:Close
IRIS MAX 11 CLS, 22.9 - 1.4
-1.0
Sets the maximum adjustment value (f)
of the IRIS control in Absolute mode.
CLS:Close
ACTIVE
MODE
12
2, 3
Selects the control mode of the ACTIVE
button.
2: FULL and LOCK modes are switched
alternately each time the ACTIVE
button is pressed.
3: FULL, PART, and LOCK modes are
switched cyclically each time the
ACTIVE button is pressed.
EXT
INDICA-
TOR
MODE
13
L , Ld
Selects the lighting mode of the EXT
indicator.
L: Links to the lens extender.
Ld: Links to the lens extender or the
digital extender of the camera.
SHUT-
TER
14
F , A
Selects the display form of the shutter
speed.
F: Frame rate
A: Angular speed
ZOOM 15
PEr , dIS
Selects the display form of the zoom
position.
PEr: Percent
dIS: Distance
Item Item
indication
(on MASTER
GAIN
indicator)
Setting
(on adjustment
value
indicator)
Function