87.5
108
MHz
531
1,602
kHz
50
dB
quieting]
ohms
(mono)
Usable
11.2
dBf,
1
pV
(IHF)
Loop
antenna:
sensitivity
75
ohms
Harmonic
0.3%
(mono),
0.5%
0.5%
(at
50
mV/m,
distortion
(stereo)
at
1.kHz
System
Preamplifier
section:
low-noise
NF
type
equalizer
amp
220—230V
AC,
50/60Hz
(for
AEP
model)
Power
consumption
In
standby
condition:
5
W
Dimensions
including
projecting
parts
and
controls
Approx.
6.4
kg
(14
lb
2
oz)
(STR-D511)
AM
loop
antenna
(1)
Tuner
section
Antenna
75
ohms,
External
antenna
terminals
terminal
38.3
dBf,
22.5
pV,
75
500
pV
(at
1,000
kHz)
400
Hz)
Frequency
30
Hz
15
kHz
response
*}°dB
Tuner
section:
PLL
quartz-locked
digital
synthesizer
Power
amplifier
section:
pure
complementary
SEPP
240V
AC,
50/60Hz
(for
UK
model)
160
W
(STR-D611)
AC
outlet
Approx.
430
x
135
x
295
mm
(w/h/d)
Mass
Accessories
supplied
Remote
Commander
RM-U232
(1)
Fane
secon
unbalanced
Sensitivity
at
|
18.3
dBf,
2.25
pV,
75
ohms
(stereo)
Signal-to-noise}
70
dB
(mono)
54
dB
(at
50
mV/m)
ratio
66
dB
(stereo)
Selectivity
60
GB
at
400
kHz
30
dB
at
9
kHz
General
system
Power
requirements
240V
AC,
50Hz
(for
Australian
model)
135
W
(STR-D511)
One
switched
(100
W
Max.)
(17x5%,
x
11
%/,
inches)
Approx.
6.9
kg
(15
Ib
4
0z)
(STR-D611)
FM
wire
antenna
(1)
Sony
batteries
SUM-3(NS)
(2)
Design
and
specifications
are
subject
to
change
without
notice.
SAFETY-RELATED
COMPONENT
WARNING!!
COMPONENTS
IDENTIFIED
BY
MARK
A
OR
DOTTED
LINE
WITH
MARK
A
ON
THE
SCHEMATIC
DIAGRAMS
AND
IN
THE
PARTS
LIST
ARE
CRITICAL
TO
SAFE
OPERATION.
REPLACE
THESE
COMPONENTS
WITH
SONY
PARTS
WHOSE
PART
NUMBERS
APPEAR
AS
SHOWN
IN
THIS
MANUAL
OR
IN
SUPPLEMENTS
PUB-
LISHED
BY
SONY.
SAFETY
CHECK-OUT
(US
Model)
After
correcting
the
original
service
problem,
perform
the
following
safety
check
before
releasing
the
set
to
the
customer:
Check
the
antenna
terminals,
metal
trim,
‘‘metallized”’
knobs,
screws,
and
all
other
exposed
metal
parts
for
AC
leakage.
Check
leakage
as
described
below.
LEAKAGE
TEST
The
AC
leakage
from
any
exposed
metal
part
to
earth
ground
and
from
all
exposed
metal
parts
to
any
exposed
metal
part
having
a
return
to
chassis,
must
not
exceed
0.5mA
(500
microampers).
Leakage
current
can
be
measured
by
any
one
of
three
methods.
1.
A
commercial
leakage
tester,
such
as
the
Simpson
229
or
RCA
WT-540A.
Follow
the
manufacturers’
instructions
to
use
these
instru-
ments.
2.
<A
battery-operated
AC
milliammeter.
The
Data
Precision
245
digital
multimeter
is
suitable
for
this
job.
3.
Measuring
the
voltage
drop
across
a
resistor
by
means
of
a
VOM
or
battery-operated
AC
volt-
meter.
The
“limit”
indication
is
0.75
V,
so
analog
meters
must
have
an
accurate
low-
voltage
scale.
The
Simpson
250
and
Sanwa
SH-63Trd
are
examples
of
a
passive
VOM
that
is
suitable.
Nearly
all
battery
operated
digital
multimeters
that
have
a
2V
AC
range
are
suitable.
(See
Fig.
A)
To
Exposed
Metal
Parts
on
Set
AC
voltmeter
as
(0.75
V)
=
Earth
Ground
Fig.
A.
Using
an
AC
voltmeter
to
check
AC
leakage.
ATTENTION
AU
COMPOSANT
AYANT
RAPPORT
A
LA
SECURITE!
LES
COMPOSANTS
IDENTIFIES
PAR
UNE
MARQUE
/\
SUR
LES
DIAGRAMMES
SCHEMATIQUES
ET
LA
LISTE
DES
PIECES
SONT
CRITIQUES
POUR
LA
SECURITE
DE
FONCTIONNEMENT.
NE
REMPLACER
CES
COM-
POSANTS
QUE
PAR
DES
PIECES
SONY
DONT
LES
NUMEROS
SONT
DONNES
DANS
CE
MANUEL
OU
DANS
LES
SUPPLEMENTS
PUBLIES
PAR
SONY.

Other manuals for Sony STR-D511

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sony STR-D511 and is the answer not in the manual?

Sony STR-D511 Specifications

General IconGeneral
BrandSony
ModelSTR-D511
CategoryStereo Receiver
LanguageEnglish

Related product manuals