Troubleshooting
In case of “Communication Error” after pressing the [Start] button, confirm the below points.
* Is the power on to the applicable amplifier?
* Are the cables connected firmly?
* Are the correct RS232C extension cables used? Always use a straight type cable.
* Is the cable connected tot the correct COM PORT number?
* Is the connected COM PORT available at PC side? Check whether the installed modem is equipped with the
port or not.
Make sure to copy the Flash Overwrite program and the latest Flash program file to the hard disk before use.
Booting up from the floppy disk may cause a failure due to a slow access speed.
In case of unsuccessful overwriting, press the [Start] button of the FAOUDJA update, and start overwriting
again from the beginning.
Overwriting may fail if any other Windows applications are run during the operation.
APPLICABLE SERIAL NUMBERS
Model Destination Colour
Serial number
UK Black 6600001~6600219
Continental Europe Silver 5500001~5501370
Continental Europe Black 5500001~5501393
Europe Silver 5500001~5503535
STR-DA3300ES
Europe Black 5500001~5503540
UK / 6600001~6600157
Continental Europe / 5500001~5501773
Europe Silver 5500001~5503081
STR-DA5300ES
Europe Black 5500001~5503286