Bias
Consumption
Current
Adjustment
This
adjustment
should
be
performed
when
replacing
the
head
assy
or
the
bias
oscillating
transformer
(T81,
T91).
Procedure
:
(
):
R-CH
digital
voltmeter
blank
tape
CS-412
|
set
LINE
IN
no
signal
1.
Connect
the
digital
voltmeter
to
test
point
TP81.
2.
Set
RV81
(RV91)
to
mechanical
center.
3.
Set
to
FWD
record
mode.
4,
Adjust
T81
(T91)
so
that
the
digital
voltmeter
reading
becomes
minimum.
Adjustment
Value
:
Maximum
220mV
Adjustment
Location
:
AUDIO
board
Record
Bias
Adjustment
Setting
:
REC
LEVEL
control
:
standard
record
position
(Refer
to
page
7.)
Procedure:
1.
Record
Mode
AE
COS
blank
tape
CS-122
3)
38.8mV(
~
26dB)
1)
315Hz
2)
10KHz
2.
Playback
Mode
recorded
VTVM
portion
I
Confirm
that
the
10kHz
playback
output
is
0
+
0.5dB
relative
to
the
315Hz
output.
If
necessary,
adjust
RV81(L-CH),
RV91(R-CH)
and
repeat
the
steps
given
above.
Adjustment
Location
:
AUDIO
board
Record
Level
Adjustment
Setting
:
REC
LEVEL
control
:
standard
record
position
(Refer
to
page
7.)
Procedure
:
1.
Record
Mode
AF
OSC
“al.
blank
tape
CS-122
I
38.8mV(
-
26dB)
attenuator
315Hz
2.
Playback
Mode
recorded
portion
Confirm
playback
the
tape
recorded
become
adjustment
level
as
follows.
If
necessary,
adjust
RV131(L-CH),
RV231(R-CH)
and
repeat
the
steps
1
and
2.
Adjustment
Value
:
LINE
OUT
level
:
26
+
0.5dB
(36.7
to
41.1mV)
Adjustment
Location
:
MAIN
board