Note
When the INPUT1 (LINE/MIC/MIC+48V) or INPUT2 (LINE/MIC/MIC+48V) switch is set to “LINE,” the standard input level is fixed
at +4 dBu. The standard input level does not change depending on the ATT switch setting.
Hint
If the noise from the jacks with no device connected is disturbing, set the INPUT1 (LINE/MIC/MIC+48V) or INPUT2
(LINE/MIC/MIC+48V) switch to “LINE.”
Related Topic
Selecting the digital or analog input type
Minimizing noise with the LOW CUT function
5-008-246-11(1) Copyright 2019 Sony Corporation
For details, see “Selecting the audio input for recording audio to the channels on the camera.”
When the device is connected to the INPUT1 or INPUT2 jack, set the standard input level of the
microphone.
When the INPUT1 (LINE/MIC/MIC+48V) or INPUT2 (LINE/MIC/MIC+48V) switch is set to either “MIC” or
“MIC+48V,” you can set the standard input level with the ATT (INPUT1) or ATT (INPUT2) switch. Select the level
suitable for the sensitivity of the connected microphone or for the volume level of the input audio.
0dB: Standard input level at -60 dBu
Suitable for recording with a low-sensitivity microphone while amplifying sounds.
10dB: Standard input level at -50 dBu
Recommended input level for the supplied microphone.
20dB: Standard input level at -40 dBu
Suitable for recording with a high-sensitivity microphone while keeping the sound volume low.
4
Adjust the recording volume level.
For detailed instructions on adjustment, see “Adjusting the recording volume level.”
5
17