Technical specifications
Sophos RED 15
Chassis Metal housing (painted white)
Power supply Input: 100-240 V AC, 50/60 Hz, 0.4 A Output: 12 V
1 .5 A
Power consumption 7 W (max.)
Dimensions W x H x D 165 x 134.8 x 34mm
Weight 600g
Temperature range Operating: 0°C to 40°C Storage: -20°C to 80°C
Humidity (non-condensing) Operating: 10% to 85% Storage: 5% to 95%
Mounting Desktop
Regulatory compliance Safety
CB IEC 60950-1:2005 (Second Edition) + A1:2009+A2:2013
CE EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
UL UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07
RCM AS/NZS 60950.1:2011+A1:2012
CCC GB 4943.1-2011
EMC
CE EN 55022:2010+AC:2011, Class B
EN 61000-3-2:2014, Class A
EN 61000-3-3:2013
EN 55024:2010
FCC 47 CFR FCC Part 15, Subpart B, Class B
ANSI C63.4:2009
IC ICES-003:2012 Issue 5, Class B
RCM AS/NZS CISPR22:2008, Class B
VCCI V-3/2015.04, Class B
V-4/2012.04
CCC GB 9254-2008
YD/T993-1998
RED 50
Scope of supply
Installation
Preliminary steps
Make sure that the RED appliance has been shipped to the branch office. Ask the
person who is going to put the RED appliance into operation at the branch office to
provide the unique RED-ID, which is printed at the bottom of the device. Note that the
RED appliance requires a working Internet connection at your branch office.
RJ45 Ethernet cableQuick Start Guide and
Safety Instructions
Sophos RED 50
Appliance
Power supply