Sorensen DCS40-25E - User Manual

Default Icon
65 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
M362500-01 Rev H www.programmablepower.com
DCS-E 1kW Series &
DCS-E 1.2kW Series
DC Power Supplies
Operation Manual
This manual covers models:
DCS8-125E DCS33-33E DCS60-18E DCS150-7E
DCS8-140E DCS33-36E DCS60-20E DCS150-8E
DCS10-100E DCS40-25E DCS80-13E DCS300-3.5E
DCS10-120E DCS40-30E DCS80-15E DCS300-4E
DCS20-50E DCS50-20E DCS100-10E DCS600-1.7E
DCS20-60E DCS50-24E DCS100-12E DCS600-2E

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Sorensen DCS40-25E and is the answer not in the manual?

Summary

Important Safety Instructions

Warranty and Returns

WARRANTY TERMS

Details the terms and conditions of the product warranty, including coverage and limitations.

PRODUCT RETURN PROCEDURE

Outlines the steps for returning a product for repair or service, including RMA requirements.

FEATURES AND SPECIFICATIONS

Specifications

Details the electrical, physical, and mechanical specifications for the DCS Series power supplies.

INSTALLATION AND OPERATION

Installation Procedures

Details essential installation steps, including voltage selection, line impedance, and ventilation.

Controls, Connectors, and Indicators

Identifies and describes the front and rear panel controls, connectors, and indicators on the power supply.

Initial Functional Tests

Details the steps for performing initial functional tests to verify proper operation before use.

TROUBLESHOOTING GUIDE

Electrical Specifications for 1 kW Models

Electrical Specifications for 1.2 kW Models

Front Panel Controls and Indicators

J3 Connector Pinout and Function

Initial Functional Tests

Standard Operation Procedures

Remote Sensing

Advanced Operation Modes

Multiple Supply Configuration

Over Voltage Protection (OVP)

Remote OVP Programming with External Voltage Sources

Remote OVP Programming with External Resistance

Remote OVP Programming with External Current Sources

Remote OVP Sensing

Remote ON;OFF Control

Remote ON;OFF by Contact Closure

Remote Programming of Output Voltage and Current Limit

Programming Output Voltage with External Voltage Sources

Programming Output Current Limit with External Voltage Sources

Programming with External Resistance

Programming Output Voltage with External Resistance

Programming Output Current Limit with External Resistance

Programming with External Current Source

Remote Monitoring and Status Indicators

Voltage Control Circuit

Current Control Circuit

Over Voltage Protection Circuit

Remote Voltage Programming

Remote Current Programming

MAINTENANCE, TROUBLESHOOTING, AND CALIBRATION

Troubleshooting

Guides users through identifying and resolving common operational issues with the power supply.

Preliminary Checks

Troubleshooting at the Operation Level

Calibration

Sorensen DCS40-25E Specifications

General IconGeneral
Output Current0-25 A
Power Rating1000 W
Frequency47-63 Hz
Efficiency≥ 85%
Output Voltage0-40 V
Dimensions444 x 89 x 406 mm
Input Voltage100-240 VAC
Operating Temperature0 to 50 °C
Storage Temperature-40 to 70 °C
CoolingFan cooled
Weight35 lbs (15.9 kg)