11
4.4 Starting
1.
2.
3.
4.
5.
6.
7.
Before connecting the controller, check the working voltage and working
frequency of the conveyor and compare them with the technical data for
the controller. The output current of 6A should not be exceeded.
Depending on the working frequency of the conveyor, set the slide
switch on the board:
Full-wave operations 50/60 Hz (slide switch above)
Half-wave operations 25/30 Hz (slide switch below)
Check the programming on the board in dependence on the type of switch-
ing and set.
Connect the conveyor to the controller.
Insert the controller's plug into the mains.
Switch the controller on.
Set the required control range with the Umin and Umax potentiometers.
5. Operating tips
1.
2.
3.
Before switching on, check that the controller is correctly plugged
into the conveyor.
Switch the controller on with a mains switch.
If required, adjust the setpoint until the vibration conveyor reaches
the desired output.
6. Repairs
Replacing fuse
1. Replace defective fuse with a 6,3 A F fuse.
Fuse is available over fuseholder in the cover.