Chapter 2 Standard specifications
8
Chapter 2
Model
Rated output
power(kW)
Rated input
current(A)
Rated output
current(A)
Adaptive
motor(kW)
ST500 250F4
250
407.9
400
250
ST500 250G4/ST500 280F4
250/280
407.9/457.4
400/449
250/280
ST500 280G4
280
457.4
449
280
ST500 315F4
315
533.2
516
315
ST500 315G4/ST500 355F4
315/355
533.2/623.3
516/570
315/355
ST500 355G4/ST500 400F4
355/400
623.3/706.9
570/650
355/400
ST500 400G4
400
706.9
650
400
AC 3PH 690V±10%
ST500 011G6/ ST500 015F6
11/15
15/20
12/15
11/15
ST500 015G6/ ST500 018F6
15/18.5
20/30
15/20
15/18.5
ST500 018G6/ ST500 022F6
18.5/22
30/35
20/24
18.5/22
ST500 022G6/ ST500 030F6
22/30
35/45
24/33
22/30
ST500 030G6/ ST500 037F6
30/37
45/55
33/41
30/37
ST500 037G6/ ST500 045F6
37/45
55/65
41/50
37/45
ST500 045G6/ ST500 055F6
45/55
65/70
50/62
45/55
ST500 055G6/ ST500 075F6
55/75
70/90
62/85
55/75
ST500 075G6/ ST500 093F6
75/93
90/105
85/102
75/93
ST500 093G6/ ST500 110F6
93/110
105/130
102/125
93/110
ST500 110G6/ ST500 132F6
110/132
130/170
125/150
110/132
ST500 132G6/ ST500 160F6
132/160
170/200
150/175
132/160
ST500 160G6/ ST500 187F6
160/187
200/210
175/198
160/187
ST500 187G6/ ST500 200F6
187/200
210/235
198/215
187/200
ST500 200G6/ ST500 220F6
200/220
235/247
215/245
200/220
ST500 220G6/ ST500 250F6
220/250
247/265
245/260
220/250
ST500 250G6/ ST500 280F6
250/280
265/305
260/299
250/280
ST500 280G6/ ST500 315F6
280/315
305/350
299/330
280/315
ST500 315G6/ ST500 355F6
315/355
350/382
330/374
315/355
ST500 355G6/ ST500 400F6
355/400
382/435
374/410
355/400
ST500 400G6/ ST500 450F6
400/450
435/490
410/465
400/450
Note: (1) ST500 inverter ST500-132G3/ST500-160F3 to ST500-630G3/ST500-700F3 with "R
suffix" indicates an integrated DC reactor, such as ST500-160G3R.
(2) The correct frequency converter selection method is: inverter rated output current is more
than or equal to the rated current of motor. The difference between the frequency inverter and the
rated power of the motor generally is recommended to be no more than two inverter power steps;
Large frequency inverter with small motor, must accurately input motor parameters, so the inverters
protection functions can avoid motor overload and damage.