Chapter 2 Standard specifications
10
Chapter 2
2-3.Standard specifications
Items
Specifications
Power Input
Rated voltage
AC 1PH 220V(-15%) - 240V(+10%)
AC 3PH 220V(-15%) - 240V(+10%)
AC 3PH 380V(-15%) - 440V(+10%)
AC 3PH 480V(-10%) - 480V(+10%)
AC 3PH 690V(-10%) - 690V(+10%)
Input frequency
50Hz/60Hz
Allowing
fluctuations
Voltage continued
volatility: ±10%
Less than 3% of voltage unbalance rate
3%
Input frequency
fluctuation: ±5%
Distortion satisfy IEC61800-2 standard
Control system
Control system
High performance vector control inverter based on DSP
Control method
V/F control, vector control W/O PG, vector control W/ PG
Automatic torque
boost function
Realize low frequency (1Hz) and large output torque control under
the V/F control mode.
Acceleration/decel
eration control
Straight or S-curve mode. Four times available and time range is
0.0 to 6500.0s.
V/F curve mode
Linear, square root/m-th power, custom V/F curve
Over load
capability
G type:rated current 150% - 1 minute, rated current 180% - 2
seconds
F type:rated current 120% - 1 minute, rated current 150% - 2
seconds
Maximum
frequency
1. Vector control:0 to 300Hz; 2. V/F control:0 to 3200Hz
Carrier Frequency
0.5 to 16kHz; automatically adjust carrier frequency according to
the load characteristics.
Input frequency
resolution
Digital setting: 0.01Hz minimum analog: 0.01Hz.
Start torque
G type: 0.5Hz/150% (vector control W/O PG)
F type: 0.5Hz/100% (vector control W/O PG)
Speed range
1:100 (vector control W/O PG) 1:1000 (vector control W/ PG)
Steady-speed
precision
Vector control W/O PG: ≤ ± 0.5% (rated synchronous speed)
Vector control W/ PG: ≤ ± 0.02% (rated synchronous speed)
Torque response
≤ 40ms (vector control W/O PG)
Torque boost
Automatic torque boost; manual torque boost(0.1% to 30.0%)
DC braking
DC braking frequency: 0.0Hz to max. frequency, braking time:
0.0 to 100.0 seconds, braking current value: 0.0% to 100.0%
Jogging control
Jog Frequency Range: 0.00Hz to max. frequency;
Jog Ac/deceleration time: 0.0s to 6500.0s
Multi-speed
operation
Achieve up to 16-speed operation through the control terminal
Built-in PID
Easy to realize closed-loop control system for the process control.
Automatic voltage
regulation(AVR)
Automatically maintain a constant output voltage when the voltage
of electricity grid changes
Torque limit and
control
"Excavator" feature - torque is automatically limited during the
operation to prevent frequent overcurrent trip; the closed-loop
vector mode is used to control torque.
Person
alizatio
n
functio
n
Self-inspection of
peripherals after
power-on
After powering on, peripheral equipment will perform safety
testing, such as ground, short circuit, etc.
Common DC bus
Multiple inverter can use a common DC bus.