Chapter 5 Function parameter
41
Chapter 5
207.
F7.02
Jog deceleration time
0.0s to 6500.0s
20.0s
208.
F7.03
Jog priority
0:Invalid 1: Valid
1
209.
F7.04
Jump frequency 1
0.00Hz to F0.19(maximum frequency)
0.00Hz
210.
F7.05
Jump frequency 2
0.00Hz to F0.19(maximum frequency)
0.00Hz
211.
F7.06
Jump frequency range
0.00Hz to F0.19(maximum frequency)
0.00Hz
212.
F7.07
Jump frequency
availability during
ac/
deceleration
process
0: Invalid 1:
Valid
0
213.
F7.08
Acceleration time 2
0.0s to 6500.0s
Depends
on
models
214.
F7.09
Deceleration time 2
0.0s to 6500.0s
Depends
on
models
215.
F7.10
Acceleration time 3
0.0s to 6500.0s
Depends
on
models
216.
F7.11
Deceleration time 3
0.0s to 6500.0s
Depends
on
models
217.
F7.12
Acceleration time 4
0.0s to 6500.0s
Depends
on
models
218.
F7.13
Deceleration time 4
0.0s to 6500.0s
Depends
on
models
219.
F7.14
Switching frequency point
between acceleration time 1
and acceleration time 2
0.00Hz to F0.19 (maximum
frequency)
0.00Hz
220.
F7.15
Switching frequency point
between deceleration time 1
and deceleration time 2
0.00Hz to F0.19 (maximum
frequency)
0.00Hz
221.
F7.16
Forward/reverse rotation
deadband
0.00s to 3600.0s
0.00s
222.
F7.17
Reverse
rotation
control
0:
Enable 1: Disable
0
223.
F7.18
Set frequency lower than
lower limit
frequency
mode
0:
running at lower limit frequency
1: stop
2: zero speed running
0
224.
F7.19
Droop control
0.00Hz to 10.00Hz
0.00Hz
225.
F7.20
Setting
cumulative
power-
on arrival time
0h to 36000h
0h

Table of Contents