459.
b0.31
ABZ incremental
encoder AB phase
sequence
0: forward 1: reverse
0
460.
b0.32
UVW encoder offset
angle
0.00 to 359.90
0
.
0
461.
b0.33
UVW encoder UVW
phase sequence
0: forward 1: reverse
0
462.
b0.34
Speed feedback PG
disconnection
detection time
0.0s: OFF
0.1s to 10.0s
0.0s
463.
b0.35
Pole-pairs of rotary
transformer
1 to 65535
1
5-1-20.y0 Group - Function code management
No.
Code
Parameter name
Setting range
Factory
setting
Chan
ge
464.
y0.00
Parameter
initialization
0: no operation
1: restore default parameter values, not
including motor parameters
2: clear history
3: restore default parameter values, including
motor parameters
4: backup current user parameters
501: restore from backup user parameters
10: Clear keyboard storage area3
11:upload parameter to keyboard storage area
1
12:upload parameter to keyboard storage area
2
21: download the parameters from keyboard
storage 1 area to the storage system 3
22: download the parameters from keyboard
storage 2 area to the storage system 3
0
465.
y0.01
User password
0 to 65535
0
466.
y0.02
Function
parameter group
display selection
Units digit: d group display selection
0: not displays 1: displays
Tens digit: E group display selection (the same
as above)
Hundreds digit:b group display selection (the
same as above)
Thousands digit:y group display selection (the
same as above)
Tens thousands digit:L group display selection
(the same as above)
11111
467.
y0.03
Personality
parameter group
display selection
Units digit:Users customization parameter
display selection
0: not display 1:display
00