3. Receiving, Unpacking, and Storage Instructions
3.1. UNPACKING AND PREPARATION
The N
2
-BLAST
®
FPS-500 will arrive in a cardboard box. Open the box carefully and identify and verify
all parts listed on the packing list are present and undamaged. South-Tek Systems (STS) is not
responsible for damages that occur during shipping and handling of the N
2
-BLAST
®
. Document any
visual damages and report them to the responsible shipping company, and then, contact STS at (888)
526-6284 to assess the damages.
Until Installation:
Store the N
2
-BLAST
®
in a dry and climate controlled (60-8F) room.
Always keep N
2
-BLAST
®
in an upright position / or, preferably, in the box as shipped.
Read entire manual and make all connections (per instructions) before connecting power.
Keep all gas lines dry so moisture does not enter generator upon hookup.
Never place/stack objects on top of the N
2
-BLAST
®
.
Remove the nitrogen generator from the cardboard box by carefully lifting the unit out and setting it on a
flat surface. Prepare the wall mounting bracket before moving it to the final location.
Note: Remove the 4 painted bolts below the cabinet to free up the compressor’s vibration isolators.
Carefully, break down the cardboard box and store in a safe location. Reuse the cardboard box if
returning for factory service.
Figure 1: Remove shipping bolts (x4)
Remove these 4
bolts underneath
the cabinet prior to
starting up the unit