OP-0210
Attention Service Person Only
INSTALLATION, SET UP & SERVICE INSTRUCTIONS
PROGRAMMABLE ELECTRIC, POWER ASSIST &
POWERPRO
®
WITH UNIVERSAL TOUCHPAD CONTROL
Subject: Function and use of 2 pin jumper locations at JP1-8.
Location JP1 – Beeper options:
No jumper: Beeper will sound when keys are pushed.
Jumper: Beeper will not sound when keys are pushed.
Location JP2 – Operating mode:
No jumper: Normal control mode. The control will initiate the appropriate move when the
code is entered.
Jumper: Locking mode. The touch pad allows the user to lock a module or a carriage.
Entering the appropriate code enables the locking. Re-entering the code disables
the locking.
Location JP3 – Not used
Location JP4 – Default reset upon power up. *
No jumper: The control will operate when the customer programmed code is used.
Jumper: The control will default to 1-2-3-4 upon power up.
Service person action required:
Symptom: The customer is unable to determine which code is active.
Cause: Someone has changed the code and has not informed the group. Could
be vandalism or an oversight.
Solution: Place a jumper at location JP4. Remove the TouchPad connector at the
back of the board and reconnect. The system will default to 1-2-3-4. Remove the jumper at
location JP4. The customer is now free to enter a new code.
Location JP5 – Jumper to enable the use of a 5-digit code.
Location JP6 – Jumper to enable the use of a 6-digit code.
Location JP5 & JP6 in combination – Jumper both to enable the use of a 7-digit code.
Location JP7 & JP8 – Reserved for future.
Note: See the drawing on the back of this page for wiring detail.
* Default codes greater than 4: (5=1-2-3-4-5) (6=1-2-3-4-5-6) (7=1-2-3-4-5-6-7)