5. Selecting an aisle with the "one touch" manual reset option:
5.1 Aisle selection with this option is identical to #2.
5.2 Once the aisle is fully open the reset lights will blink on either side of
the selected aisle.
5.3 No new aisle selection can be made until the reset button on either
side of the open aisle is pressed, canceling the locked aisle condition.
Note: The closing of a safety faulted aisle is not possible without the use
of the safety override key. Please see your supervisor for
instructions regarding the safe use of the safety override key.
6. Using the optional photoelectric safety sweep:
6.1 If carriage movement begins while you are in the aisle, it can be
stopped by breaking the invisible light beam constantly being
projected along the entire length of each carriage. If an obstruction of
any kind is detected, the carriages will come to an abrupt stop. The
beam sweeps for obstructions close to the floor.
6.2 The safety sweep may also prevent damage to material left laying in
the aisle.
CAUTION!: Remember that sweep activation must be done from
floor level. Therefore, never climb on the shelves!
6.3 When a safety sweep has been activated during carriage travel the red
light just above the RESET button will begin to blink and all system
function will cease. A press of the RESET button will turn the blinking
light to steady.
6.4 If it is not possible to remove the obstruction in the aisle the following
procedure can be used. Press a RESET button under the blinking red
light. The red light will stop blinking and turn steady. Gently press the
appropriate move button to open the safety locked aisle. The safety
locked aisle will fully open, allowing entry and removal of the
obstruction. Normal operation has now been restored.
7. Using the Electro - Mechanical Safety Sweep:
7.1 If carriage movement should begin while you are in the aisle, it can be
stopped abruptly by applying pressure to the safety sweep located
along the full length of each carriage just above floor level. The safety
sweep can also help prevent damage to media left laying in the aisle.
7.2 The safety sweep may also prevent damage to material left laying in
the aisle.
CAUTION!: Remember that sweep activation must be done from
floor level. Therefore, never climb on the shelves!
7.3 When a safety sweep has been activated during carriage travel the red
light just above the RESET button will begin to blink and all system
function will cease. A press of the RESET button will turn the blinking
light to steady.
7.4 If it is not possible to remove the obstruction in the aisle the following
procedure can be used. Press a RESET button under the blinking red
light. The red light will stop blinking and turn steady. Gently press the
appropriate move button to open the safety locked aisle. The safety
locked aisle will fully open, allowing entry and removal of the
obstruction. Normal operation has now been restored.