EasyManua.ls Logo

SPAL FAN-PWM-V3 - Setting The Low Temperature Only; Setting The High Temperature Only

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.spalusa.com
13
Programming
(continued)
1. Press and Hold down PRG button for 5 seconds.
2. Fan will stop running and ‘FAN’ LED will be slowly blinking AMBER.
3. Press PRG button once.
4. ‘FAN’ LED will be slowly blinking RED.
5. Warm engine up to desired HIGH temperature and press ENTR button to
set HIGH.
6. The ‘STAT’ LED will blink once then the ‘FAN’ LED will be slowly blinking
GREEN.
7. Press PRG button once to EXIT programming.
Setting The High Temperature Only:
Setting The Low Temperature Only
1. Press and Hold down PRG button for 5 seconds.
2. Fan will stop running and the ‘FAN’ LED will be slowly blinking AMBER.
3.
Warm engine up to desired LOW temperature and press ENTR to set LOW.
4. The ‘STAT’ LED will blink once and the ‘FAN’ LED will turn RED and be
blinking slowly.
5. Press PRG button 2 times to EXIT programming.