SV Series Spa Controls 21
Setup Menu
How to program advanced configuration settings
Press to confirm & save
Press to enter adjustment
Press and hold +
IMPORTANT NOTES
The setup menu item settings are stored in non volatile memory (EEPROM) and
are remembered when power is turned off. No need to reprogram settings when
power is restored.
A ten (10) second idle menu time out period exists. If a button press is not detected
for 10 seconds the menu will time out and the screen will return to the default
display mode.
Setup Menu
The SV controllers feature an advanced setup menu which allows customisation of the
adjustable controller settings. Menu item options are detailed in the list below.
To enter menu press and hold and buttons until [MODE]
is displayed
Press or to navigate through menu item list
Press to enter menu item adjustment
Press or to adjust setting
Press to confirm setting and exit menu
Menu
Item
Setting Notes
MODE Operating Mode Normal / Economy / Away / Week Modes
FILT Hours of filtration per day 1 to 24 hours
F.CYC Filtration cycle blocks Set filtration to run every 1,2,3,4,6,8,12 or 24 hrs
SNZE Sleep time menu
1.SNZ Sleep timer 1
[1.DAY] Days of week, [1.BGN] Begin Time, [1.END] End
Time
2.SNZ Sleep timer 2
[2.DAY] Days of week, [2.BGN] Begin Time, [2.END] End
Time
R.SET Reset sleep timers Reset sleep timers to factory defaults
EXIT Exit sleep time submenu
P.SAV Power save settings Off, Low (off-peak filtration), High (off-peak filtration & heating)
W.CLN Automatic sanitise time Daily run time of automatic sanitise cycle (00:00 - 23:59)
D.DIS Default display mode Water Temp (W.TMP), Set Temp (S.TMP) or Clock (TIME)
T.OUT Load time out period Pump / Blower time out period (10 to 60 minutes)
H.PMP
Heat pump
operating mode
Auto (heat or cool) / Heat / Cool / Off (heat pump
disabled)
H.ELE
Heat pump with
SV element boost
On = Heat pump + SV element combined for heating
Off = Heat pump only
EXIT Exit setup menu