| Type | Load Cell Amplifier |
|---|---|
| Output Data Rate | 10Hz or 80Hz |
| Package | SOP-16 |
| Operating Temperature | -40°C to +85°C |
| Differential Input Voltage | ±20mV |
| Resolution | 24-bit |
| Sampling Rate | 10Hz or 80Hz |
| Input Voltage | 2.7V to 5.5V |
| Communication Interface | Serial |
| Gain | 128, 64, 32 |
| Current Consumption | 1.5mA |
| Input Channels | 2 Differential |
Lists the essential components required for setting up the load cell amplifier and connecting it.
Details mounting bar load cells between plates using screws and spacers for accurate strain measurement.
Explains how to mount smaller disc load cells by centering them on the button for precise force measurement.
Describes the conventional color coding of load cell wires (RED, BLK, WHT, GRN, YLW) and their connection to the amplifier.
Details how to connect load cells to the HX711 amplifier, including VDD, VCC, DAT, CLK, and GND connections.
Explains connecting four load sensors to the combinator board and then to the HX711 amplifier.
Guides on using calibration and example code for the HX711, including library sources.