LIST OF VULNERABLE PARTS
Description Models or specications
Spark Plug LD L8RTF/902700
Chain bar 160SDEA041
Saw chain PJ057X
MAINTENANCE AFTER EACH USE
WARNING! Before cleaning, inspecting or repairing
your unit, make sure that the engine has stopped
and is cool. Disconnect the spark plug to prevent
accidental starting.
1. Air filter
Dust on the air filter surface can be removed by detaching
the air filter cover (A), removing the filter and tapping a
corner of the filter cover (B) against a hard surface. To clean
dirt in the meshes, brush in petrol. When using compressed
air, blow from the inside.