5
4.2 PLUMBING CONNECTION
4.2.1 The piping should be as direct and free from turns or bends as possible as elbows and other
ttings can greatly increase friction losses.
4.2.2 If the pump is located below water level, isolation valves must be installed on both sides of the
pump to prevent the back ow of pool water during any routine or required servicing.
4.2.3 Use PVC ttings for all connections. A 50mm (2") suction / inlet Union is provided and a 40mm
(1.5") discharge / outlet Union is provided. The suction and discharge pipes must not be smaller
in diameter than the pump ttings (otherwise ow rates may be aected).
4.2.4 Use plumbing Cleaner Primer to clean and prepare the pipe ends and Union Sockets. Place
the Union Collars over the pipe ends. Using plumbing Solvent Cement glue the Union Sockets
to the pipe ends. Allow at least 24 hours for any adhesive to dry thoroughly before starting the
pump.
4.2.5 Ensure that the O-rings are tted to the Union Sockets and apply a suitable O-ring lubricant
if required. Also check that the pump basket lid O-ring is suciently lubricated.
4.2.6 Connect the Unions to the pump by tightening the Union Collars by hand (do not use any tools
to tighten the collars as damage may occur).
4.2.7 Suction and discharge lines should be independently supported at a point near the pump to
avoid strains being placed on the pump.
4.3 ELECTRICAL CONNECTION
4.3.1 Speck Pool and Spa pumps are suitable for connection to a nominal 230VAC 50hz power
supply.
4.3.2 The motor is equipped with a exible cable and 3-pin plug. If a power outlet is not available
within 2 meters of the pump, a 3-pin power point in a safe dry place will need to be provided
by an electrician.
4.3.3 The pump power must be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
4.3.4 Extension cords are unsafe around pools and must be avoided
5.0 OPERATION
5.1 GENERAL START UP GUIDE
5.1.1 CAUTION: Never run the pump without water. Running the pump “dry” for any length of time
can cause severe damage to both the pump and the motor and will void the warranty.
5.1.2 If it is a new pool installation, make sure all piping is clear of construction debris and has been
properly pressure tested. Special care must be taken to ensure no small pebbles are ingested
into the pump as this voids the warranty.
5.1.3 The lter should be checked for proper installation, verifying that all connections are secure
according to the manufacturer’s recommendations.

Related product manuals